Trouble shooting guide – Napoleon Fireplaces GSS36N Manuel d'utilisation

Page 11

Advertising
background image

11

W415-0369 / E / 02.16.07

Main burner goes
out; pilot stays on.

Pilot fl ame is not large enough
or not engulfi ng the thermo-
pile

- turn up pilot fl ame.
- replace pilot assembly.

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.

Remote wall switch wire is too
long; too much resistance in
the system.

- shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

- replace.

Pilot will not light.

- check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.

No spark at pilot burner

- fi ll the tank.

Out of propane gas
Spark gap is incorrect

- spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from
the electrode tip and the pilot burner. To ensure proper electrode loca-
tion, tighten securing nut (fi nger tight plus 1/4 turn).

No gas at the pilot burner

- check that the manual valve is turned on.
- check the pilot orifi ce for blockage.
- replace the valve.
- call the gas distributor.

Pilot goes out when
the gas knob is re-
leased.
The gas valve has
an interlock device
which will not al-
low the pilot burn-
er to be lit until
the thermocouple
has cooled. Allow
approximately 60
seconds for the
thermocouple to
cool.

System is not correctly
purged.

- purge the gas line.

Out of propane gas.

- fi ll the tank.

Pilot flame is not large
enough

- turn up the pilot fl ame.

- gently twist the pilot head to improve the fl ame pattern around the
thermocouple.

Pilot fl ame is not engulfi ng the
thermocouple.
Thermocouple shorting /
faulty.

- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.

Faulty valve.

- replace.

Pilot burning; no
gas to main burner;
gas knob is on ‘HI’;
wall switch / ther-
mostat is on.

Themostat or switch is de-
fective.

- connect a jumper wire across the wall switch terminals; if main burner
lights, replace switch / thermostat.

Main burner orifi ce is plugged. - remove stoppage in orifi ce.

Faulty valve.

- replace.

Wall switch wiring is defec-
tive.

- disconnect the switch wires & connect a jumper wire across terminals
1 & 3; if the main burner lights, check the wires for defects and / or
replace wires.

TROUBLE SHOOTING GUIDE

SYMPTOM

PROBLEM

TEST SOLUTION

Advertising