Troubleshooting, Cont.) – Panasonic BT-H1700P Manuel d'utilisation

Page 20

Advertising
background image

Problems

Irregular colour

Wrong picture
position, wrong
picture size

Front panel
buttons and
knobs do not
function

Points to be checked

Is the monitor placed or moved close to
a speaker or any other device
incorporating a magnet?
Has the position of the monitor been
changed with the power on?

Has the picture position, size or
distortion been changed?

Have the UNDER SCAN or ASPECT
button been pressed?

Has the CONTROL LOCK function
been set to ON?

Has the monitor’s setting been
changed to enable control from an
external unit via the REMOTE
terminals?

Measures (Remedy)

Move the device away from the monitor.
Press the DEGAUSS button on the front panel to
degauss the screen.
When degaussing, wait more than 30 minutes for
maximum effect.

Adjust the picture size (H SIZE, V SIZE) or
position (H. POSITION, V. POSITION) in the
[SIZE/POSI. ADJ.] item in the <SETUP MENU>
screen.
Adjust the picture distortion (PINCUSHION, PIN.
BALANCE, TRAPEZOID and PARALLELOGRAM)
in the [DISTORTION ADJ.] item in the <SETUP
MENU> screen.
It may not be possible to expand the picture due
to the selected input mode. In this case,
adjustment is impossible.

When the UNDER SCAN or ASPECT button is
lit, press each button to invalidate each setting.

Set the CONTROL LOCK function to OFF.

Change the setting of the external control to
control the monitor locally.

The following are not malfunctions:

● You may see two horizontal lines on the monitor. They are

the shadows of the “damper lines” that are necessary for
composing the monitor. These lines are not a malfunction.

● When a bright still image (such as a white cloth) is

displayed for a long period, it may appear to be coloured.
This is due to the structure of the cathode ray tube and
will disappear when another image is displayed.

● You may sometimes experience a mild electric shock

when you touch the picture tube. This phenomenon is due
to a normal buildup of static electricity on the CRT and is
not harmful.

● The monitor emits a strange sound when the room

temperature changes suddenly. This is only a problem if
an abnormality appears on the screen as well.

● If two or more monitors are operated next to each other,

their images may shake or be distorted. This phenomenon
is due to mutual interference; it is not a malfunction. Move
the monitors away from each other until the interference
disappears or turn the power off on any monitor that is not
being used.

VOLUME

SLOT 1

A

B

DEGAUSS

MENU

BLUE

CHECK

ASPECT

AREA

MARKER

UNDER

SCAN

PULSE

CROSS

COLOR

OFF

SLOT 2

C

D

SLOT 3

POWER

E

F

INPUT SELECT

TROUBLESHOOTING

(cont.)

Reference

pages

4

15, 16

4

16

17, 18

Damper line

20

Advertising