Operating Options

Your stove comes equipped with an “On/Off” rocker switch used to turn

the burner on and off while the pilot light is on. The switch is a round

rocker switch located behind the main control panel door.

A millivolt wall thermostat, or a remote control, can be used to supple­

ment the rocker switch. The gas valve is powered by millivolts generated

by the pilot assembly. This millivolt system is very sensitive to electrical

resistance, therefore, make sure all connections are tight, clean and free

from corrosion. Do not splice any millivolt wires. Consult the table below

to determine the proper gage of wire for the thermostat or wall switch

connections. This table refers to the total length of the wire (out to the

switch and back). The thermostat must be a millivolt type. A 24­volt

furnace thermostat will not work. Never hook up household current ­ 120

Volts ­ to the millivolt system. It is not recommended to hook up any

more than two switches to the stove (for example a rocker switch and a

wall thermostat). Additional switches may affect the system resistance

and increase the chance of the burner not igniting.

Follow the instructions included with the thermostat or remote control

for wiring. The thermostat, remote control and rocker switch will turn the

burner on and off independently. Be sure to set the rocker switch to the

“Off” position when using the thermostat or remote control and set the

thermostat or remote control to the lowest temperature when you wish

to use the rocker switch only, otherwise one may override the other.

Millivolt Control System

This stove operates on a millivolt control system. As such, no additional
power supply is needed for the stove to heat. The pilot assembly contains
a thermocouple that, when heated by the pilot flame, generates electricity
(millivolts­ mV=1/1000 of a volt) which opens a valve allowing gas to
continue flowing to the pilot assembly. The pilot assembly also contains a
thermopile that, when heated by the pilot flame, generates electricity that
flows to terminal #1 (labeled TPTH) on the gas valve. When the electricity
is conducted from terminal #1 through the on/off switch, thermostat,
or receiver of the remote control to terminal #3 (labeled TH) on the gas
valve, the main burner will ignite.

CAUTION: Label all wires prior to disconnection when servic-

ing controls. Wiring errors can cause improper and dangerous

operation.

ATTENTION: Au moment de l'entretien des commandes,

étiquetez tous les fils avant de les débrancher. Des erreurs

de cáblage peuvent entraîner un fonctionnement inadéquat

et dangereux.

Figure 27

Millivolt Control Schematic

Thermopile

ON/OFF Rocker Switch,

Thermostat, or Remote

Thermostat

Piezo Igniter

Thermocouple

Pilot

Gas

Line

Sparker

Pilot Hood

Pilot Assembly

Gas Inlet

Pressure Taps

Terminal 3

Terminal 1 Terminal 2

Gas Valve

Wiring Terminals

Thermostat Wire

Wire Size

Maximum Length

12 Gage

100 Feet

14 Gage

64 Feet

16 Gage

40 Feet

18 Gage

25 Feet

20 Gage

16 Feet

PILOT

OFF

ON

HI

LO

PILO

T

TPTH

TP

TH

1

2

3

1

2

3