Vent Parts List

Secure Vent™ direct­vent pipe by Security Chimneys™* may be used with
this appliance. Please see the lists below to verify the components avail­
able from each direct­vent pipe manufacturer. Snorkel terminations are
available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.

Security - Secure Vent 6-5/8”x 4” Pipe

Part Number

Description

SV4LC

6” Pipe Length

SV4L12

12” Pipe Length

SV4L24

24” Pipe Length

SV4L36

36” Pipe Length

SV4L48

48” Pipe Length

SV4LA

6” Pipe, Adjustable

SV4LA12 12” Pipe, Adjustable

SV4FA

Flashing, 1/12 to 6/12 Roof Pitch

SV4FB

Flashing, 7/12 to 12/12 Roof Pitch

SV4RSM

Wall Radiation Shield

SV4E46

45º Elbow

SV4E90

90º Elbow

SV4VS

Vinyl Shield Protector

SV4FC

Storm Collar

SV4CGV

Vertical Termination Cap

SV4BF

Firestop

SV4CHC

Horizontal Termination Cap

SV4STC36

Snorkel Termination Cap (36”)

SV4STC14

Snorkel Termination Cap (14”)

SV4BM

Wall Band

Simpson Dura­Vent GS 6­5/8”x 4” Pipe

Part Number

Description

908

6” Pipe Length

907

9” Pipe Length

906

12” Pipe Length

904

24” Pipe Length

903

36” Pipe Length

902

48” Pipe Length

911

11” to 14­5/8” Pipe, Adjustable

942

Wall Thimble

940

Rnd Support Box/Wall Thimble Cover

941

Cathedral Ceiling Support Box

943

Flashing, 0/12 to 6/12 Roof Pitch

943S

Flashing, 7/12 to 12/12 Roof Pitch

945

45º Elbow

990

90º Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

988

Wall Strap

981

Snorkel Termination (36”)

982

Snorkel Termination (14”)

984

Horizontal Termination Cap

985

Horizontal Termination Cap (High Wind)

980

Vertical Termination Cap

991

Vertical Termination Cap (High Wind)

Horizontal Vent Installation

Venting terminals may not be recessed into a wall or siding.

1) Set the unit in the desired location. Check whether or not wall studs

are in the way when the venting system is attached. If wall studs are
in the way, you may want to adjust the location of the unit.

2) Assemble the desired combination of pipe and elbow to the appliance

adaptor with pipe seams facing down. Offsetting the pipe seams as
double seams in one place will cause the outer pipe to take an oval
shape. The Horizontal Termination Kit comes with 18” of straight vent
­ 6­5/8” black outer pipe and 4” inner vent.

3) With the pipe attached to the stove, slide the stove into its correct

location and mark the wall to the dimensions of the wall thimble
(9­1/4” x 10­1/4”). The center of the round hole should line up with
the centerline of the horizontal pipe. (9­1/4” is side­to­side dimen­
sion and 10­1/4” is vertical dimension) If the wall being penetrated
is constructed of non­ combustible material (i.e. masonry block or
concrete), a 7” diameter hole is acceptable.

4) The horizontal run of vent should have a 1/4” rise for every 1 foot of

run toward the termination. Never allow the vent to run downward.
This could cause high temperatures and may present the possibility
of a fire.

5) The location of the horizontal vent termination on an exterior wall must

meet all local and national building codes and must not be blocked
or obstructed. For External Vent Termination Locations, see Page 17.

Snorkel Terminations:

For installations requiring a vertical rise on

the exterior of the building, 14­inch (356 mm) and 36­inch (914 mm) tall
Snorkel Terminations are available, as well as the standard Riser Vent.
Follow the same installation procedures as used for standard Horizontal
Termination. NEVER install the snorkel upside down.

Typical parts needed for a horizontal installation.

14” Snorkel for Vision 35

Standard Horizontal for Vision 25

Wall Thimble

Decorative Wall Trim

Pipe Length

max

min

Snorkel required for Vision 35 or

Vision 25 if horizontal run

exceeds 3 feet.