Warning, Electrical connection - u.s.a. only – KITCHENAID W10246119C Manuel d'utilisation

Page 9

Advertising
background image

9

6. Align anti-tip bracket holes with holes in floor. Fasten anti-tip

bracket with screws provided.

Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.

7. Move range close enough to opening to allow for electrical

connections to be made. Remove cardboard or hardboard
from under range.

8. Make electrical connections as described in the “Electrical

Connection” section.

9. Move range into its final location, making sure rear leveling

leg slides into anti-tip bracket.

10. Continue installing your range using the following installation

instructions.

Electrical Connection - U.S.A. Only

1. Disconnect power.

2. Remove the terminal block cover screws located on the back

of the range. Pull cover down and toward you to remove
cover.

3. Remove plastic tag holding three 10-32 hex nuts from the

middle post of the terminal block.

4. Add strain relief.

Style 1: Power supply cord strain relief

Remove the knockout at the bottom of the terminal box
for the 40-amp supply cord.

Power Supply Cord

Direct Wire

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death,
fire, or electrical shock.

A. Hold-down screws
B. Terminal block cover

A

B

Advertising