Assemble a UL listed strain relief in the opening.

Feed the power supply cord behind the black horizontal
cross brace and through the strain relief, allowing enough
slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.

Style 2: Direct wire strain relief

Remove the knockout as needed for the flexible conduit
connection.

Assemble a UL listed conduit connector in the opening.

Feed the flexible conduit behind the black horizontal
cross brace and through the strain relief, allowing enough
slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the flexible conduit.

5. Complete installation following instructions for your type of

electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)

Electrical Connection Options

A. UL listed strain relief

A. Black horizontal cross brace
B. Power supply cord

A. Removable retaining nut
B. UL listed strain relief

A

B

A

A

B

A. Black horizontal cross brace
B. Flexible conduit

If your home has:

And you will be
connecting to:

Go to Section:

4-wire receptacle
(NEMA type 14-50R)

A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord

4-wire connection:
Power supply cord

4-wire direct

A fused
disconnect or
circuit breaker
box

4-wire connection:
Direct wire

3-wire receptacle
(NEMA type 10-50R)

A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord

3-wire connection:
Power supply cord

3-wire direct

A fused
disconnect or
circuit breaker
box

3-wire connection:
Direct wire

B

A

(12.7 cm)

5"

3"

(7.6 cm)

³⁄₈

"

(1.0 cm)