4-wire connection: Power Supply Cord

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the
neutral.

1. Cut out and remove part of the metal ground strap (B).

2. Use a Phillips screwdriver to remove the ground-link screw

from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.

3. Feed the power supply cord through the strain relief on the

cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.

4. Use a Phillips screwdriver to connect the green ground wire

from the power supply cord to the range with the ground-link
screw and ground-link section. The ground wire must be
attached first.

5. Use

³⁄₈" nut driver to connect the neutral (white) wire to the

center terminal block post with one of the 10–32 hex nuts.

6. Connect line 2 (red) and line 1 (black) wires to the outer

terminal block posts with 10-32 hex nuts.

7. Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1

³⁄₈" (3.5 cm) diameter

connection opening, with ring terminals and marked for use
with ranges.

8. Tighten strain relief screws.

9. Replace terminal block access cover.

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.

1. Feed the power supply cord through the strain relief on the

cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.

A. Metal ground strap
B. Discard

C. Ground-link screw

A. Terminal block
B. Ground-link screw

C. UL listed strain relief
D. Power supply cord wires

A

B
C

A

B

D

C

A. 10–32 hex nut
B. Ground-link screw

C. Line 2 (red)

D. Green ground wire

E. Neutral (center) wire

F. Line 1 (black)

A. Terminal block
B. Ground-link screw

C. UL listed strain relief
D. Power supply cord wires - large opening

A

B

C

F

D

E

A

B

D

C