Faber Pro Magnum Manuel d'utilisation

Page 6

Advertising
background image

Version 04/08 - Page 6

INSTALL THE RANGEHOOD

1. Remove the unit from the carton and place on a flat

surface for assembly. Cover the surface to prevent accidental

damage. Remove all parts including the mounting hardware

before discarding the carton.

2. Remove the grease filters USING TWO HANDS (one to

hold the filter so that it doesn't fall on cooktop and one to turn

the knob) by pulling the knob out and turning to the left.

3. The rangehood is shipped from the factory in the up vent

position as indicated in FIGURE 9. For top vent applications,

no additional adjustments are necessary.

FIGURE 9

For rear vent applications, the blower must be turned inside the

rangehood so that the blower vents to the rear as indicated in

FIGURE 10. The blower is turned by removing two screws on

each side of the blower, rotating the blower with the exhaust

opening facing the rear and then replace the screws. The

exhaust cover must be moved to block the unused opening. The

blower must be converted before installing the rangehood.

FIGURE 11

FIGURE 10

4. Remove the cover from the field wiring compartment.

Remove the wiring electrical knockout using a flat-blade

screwdriver. Feed the Power Supply Cable through the

electrical knockout.

5. The canopy attaches to the wall by two screws discussed

earlier in the installation instructions. The canopy hangs

from these screws by brackets inside the rangehood shown

in FIGURE 11. Before attempting to hang the canopy, you

should rotate the adjustment screw marked V1 in FIGURE

11 counterclockwise to extend the brackets from the

canopy. Using a Phillips head screwdriver, rotate this screw

counterclockwise to extend the bracket.

6. Install the damper before hanging the rangehood. The

damper attaches to the rangehood by two small screws

provided in the hardware package. If 48" hood is to be

connected to 10" round duct, install the Duct Transition Kit

now.

7. Hang the rangehood canopy from the screws. Due to

the weight of the canopy, these screws must be installed into

solid material! Once the canopy is hung, rotate the screw

marked V1 to secure the rangehood to the wall.

MAKE SURE THAT THE RANGEHOOD IS SECURELY

ATTACHED TO THE WALL! FAILURE TO PROPERLY

INSTALL COULD RESULT IN INJURY OR DAMAGE TO

PROPERTY.

8. The brackets shown in FIGURE 11 are also used to

adjust the level of the canopy. Using a Phillips screwdriver,

rotate the screw V2 to adjust the level of the canopy.

9. Connect the Power Supply Cable to the rangehood.

Attach the White lead of the power supply to the White lead

of the rangehood with a twist-on type wire connector. Attach

the Black lead of the power supply to the Black lead of the

rangehood with a twist-on type wire connector. Connect the

Green ( Green and Yellow ) ground wire under the Green

grounding screw.

10. Replace the field wiring compartment cover and the

grease filters.

11. If the installation uses a telescopic chimney, connect the

ductwork and install the chimney. Mount the upper chimney

section to the wall first. Then mount the lower section. The

lower section fits over the upper section.

If the installation uses a full width duct cover, install it now.

12. Turn the power supply on. Turn on blower and light.

The rangehood controls are located on the right-hand side

under the canopy. If the rangehood does not operate, check

that the circuit breaker is not tripped or the house fuse blown.

If the unit still does not operate, disconnect the power supply

and check that the wiring connections have been made

properly.

Advertising