Faber Pro Magnum Manuel d'utilisation

Page 5

Advertising
background image

Version 04/08 - Page 5

PREPARE THE WALL

1. Disconnect and move freestanding range from cabinet

opening to provide easier access for installation. Put a thick,

protective covering over cooktop, set-in range or countertop

to protect from damage or dirt.

2. Determine and clearly mark with a pencil the center line

on the wall where the rangehood will be installed.

3. The Pro Magnum attaches to the wall by mounting

screws indicated in FIGURE 5. For the 30" and 36" models,

there are two mounting screws. For the 48" model, there are

four mounting screws. Install the screws into the wall. The

screws should be inserted into the wall until the screw head

is flush with the wall.

WARNING: THE SCREWS PROVIDED FOR MOUNTING

THIS RANGEHOOD MUST BE INSERTED INTO SOLID

WOOD. THESE MUST NOT BE INSERTED INTO SHEET

ROCK.

Determine the proper location for each bracket and install the

brackets on the wall. MAKE SURE THAT THE SCREWS

AND BRACKETS ARE SECURELY FASTENED TO THE

WALL.

5. Determine and make all necessary cuts in the wall for

the ductwork. The Pro Magnum vents either through the top

or the rear of the rangehood. Each rangehood is shipped from

the factory vented through the top. In order to vent to the rear,

the blower inside the rangehood must be turned to the rear.

The dimensions for the duct openings are given in FIGURE

8. The 48" model uses two 3 & 1/4" by 10" duct openings.

Install all ductwork before installing the rangehood.

6. Determine the proper location for the Power Supply

Cable as indicated in FIGURE 8. Note that the 30"/36"

versions have the option of top or rear electrical connection

while the 48" version has only the rear option. Use a 1 & 1/4"

Drill Bit to make this hole. Run the Power Supply Cable. Use

caulking to seal around the hole. DO NOT turn on the power

until installation is complete.

FIGURE 8

4. The Telescopic Chimney Kit and Full Width Duct

Cover use different bracket systems to attach to the wall.

FIGURE 6 provides the position for the telescopic chimney

brackets.

48" VERSION

30" AND 36" VERSIONS

FIGURE 7

FIGURE 5

FIGURE 6

FIGURE 7 provides the dimensions for the Full Width Duct

Cover brackets. The Full Width Duct Cover also attaches to

the top of the rangehood with screws provided. The Full Width

Duct Cover must be attached to the top of the rangehood

before mounting the rangehood to the wall.

Electrical Opening

Electrical Opening

If a backsplash is to be used with this rangehood, it must be

installed before the rangehood. Installation instructions for

the backsplash are supplied in its box. The height of the

backsplash will determine the bottom edge of the canopy.

Advertising