B.1.4 WATER CONNECTION

The appliance is equipped with a drain hole for draining any
liquids collected in the compartment.
Connect the hole “C”, located on the bottom of the appliance and

closed with a plug, to a special drain.
The diameter of the drain hole is “0.69” / 17.5 mm”; therefore
it is advisable to connect it to a hose of diameter “0.69” / 17.5

mm”.
Note: Discharge must be into an open drain through a trap, to
prevent any backflow from the sewage network reaching the

pipes inside the appliance.

If the equipment is installed in places where there are corrosive

substances (chlorine, etc.), it is advisable to go over all the
stainless-steel surfaces with a cloth moistened with paraffin
oil in order to create a protective film.

The maximum room temperature at which the appliance can
operate is +109.4°F/+43°C.

B.1.3 ELECTRICAL CONNECTION
When making the electrical connection, respect that given on
the dataplate.
The appliance uses a single-phase 115V/60Hz power supply.

IMPORTANT:

Connection to the power supply must be carried out in compliance

with current regulations and the standards required by the
National Electric Code (NEC), known as NFPA 70.

Make sure connection to the power supply is carried out in
compliance with the current regulations.
Before connecting make sure:
- The cable is correctly grounded and that the power supply

complies with the frequency given on the dataplate. In case of
doubts regarding the efficiency of the earth connection have
the system checked by qualified personnel.

- The appliance must be connected to the power supply in a

permanent way.

- To protect the appliance from possible overloads or short-

circuits, the electric line powering the appliance MUST be
equipped with a mains circuit breaker or main switch (provided
for by the customer). The switch must have cutoff capability.

Before making any electrical connections to the appliance,
check that the power supply complies with the voltage,
amperage and phase given on the dataplate. The Customer

must also provide a cable with ground connection of capacity
suitable for that given on the dataplate.

- After making the connection and with the appliance operating,

check that the rated voltage level does not fluctuate by ± 10%.

Connection must be made with a cable suitable for the amperage
and voltage.

The manufacturer declines any liability for damage or injury
due to non-compliance with the above rules or the current
safety regulations in the country where the equipment is

used.