eNeRCo GRoUP, INC. |Indirect Fired Portable Heater

operating Instructions and owner’s manual

1

CoNTRol lAmP

2

CONTROL KNOB HEAT - STOP - VENTILATION ONLY

3

PoWeR CoRD FAsTeNeR

4

oVeRHeAT sAFeTY THeRmosTAT, l1

5

FAN THeRmosTAT, F

6

LIMIT THERMOSTAT WITH MANUAL RESTART, L2

7

THeRmosTAT ReseT sWITCH

8

HoUR CoUNTeR

9

OVERHEAT THERMOSTATS CONTROL LAMP, L1, L2

10 FAN sToP CoNTRol lAmP

11 HeATeD DIesel FIlTeR PlUG

12 BURNeR PlUG

13 Room THeRmosTAT PlUG

Control Board

INSTALLATION

wARNINg

THe FolloWING oPeRATIoNs mUsT Be CARRIeD oUT

BY QUAlIFIeD PeRsoNNel oNlY.

Electrical Connections Settings

every space heater is supplied along with the safety and control
devices which are indispensable to the correct functioning of
the unit. The electric switchboard, burner, the fan thermostat,
overheat safety thermostat and the overheat thermostat with
manual restart have already been connected.

wARNINg

PoWeR sUPPlY CoRD oF PRoPeR DImeNsIoN

sHAll Be CoNNeCTeD To THe mAIN sWITCHBoARD
AND HeATeR sHAll Be GRoUNDeD. eleCTRICAl
GRoUNDING sHAll Be IN ComPlIANCe WITH THe
NATIoNAl eleCTRICAl CoDe ANsI/NFPA 70 oR THe
CSA C22.1 CANADIAN ELECTRICAL CODE, PART I.

The following operations must now be carried out:

• Plug in the power cord having read the adhesive label which

details electricity supply characteristics.

• The burner must be connected to the fuel supply (Burner

Instruction manual).

• Connect the burner to the electricity supply with the burner

plug.

• Connect accessories such as the room thermostat or clock to

the unit’s electric switchboard with the thermostat plug.

Having completed all these operations check carefully that all
electrical connections correspond to the wiring diagram. When
the heater is first turned on you must check that the fan does not
use more current than the maximum permitted limit.

Finally, to regulate the burner, follow the instructions in the Burner
Instruction manual.

INSTRUCTIONS FOR USE

Switching On

• Set the control knob (2) in position “0”.
• Turn on the disconnecting switch on the electric

switchboard.

• If the unit is operated manually turn the control knob to

.

The burner starts up, the combustion chamber heats up and
then the fan starts.

• If the unit operates automatically set the room thermostat

at the desired level and turn the control knob (2) to : the
heater will now start and stop automatically.

• If the heater doesn’t start after you have completed the

above operations consult the Troubleshooting section of this
manual.

Turning Off

In manual operation turn control knob (2) to “0” or turn off
control in automatic operation.

The burner stops while the fan turns itself on and off until the
combustion chamber has completely cooled down.