Format de sortie de la liste des paramètres – HEIDENHAIN ND 281 B v.2 Manuel d'utilisation
Page 56

56
Liste des paramètres du ND 281 B: Mode de fonctionnement „Mesure angulaire” (configuration par défaut)
Liste des paramètres
Description
*
Caractère de début (*);
ND-281 B DEC
Appareil; DEC (décimal) ou DMS (min./sec.);
P02
X1/X2 =
X1 11 uACC =
0
Entrée système de mesure: X1 11µACC = 0; X2 1VCC = 1;
P08
AFFICH. =
DEGR. DECIM =
0
Affichage: DEGR. DECIM. = 0; DEGR.MIN.SEC = 1;
P09
ANGLE =
+/-180 DEGR =
0
Angle: +/- 180 DEGR = 0; 360 DEGR = 1; INFINI = 2;
P17
CLASS. =
CLASS. OFF =
0
Classification: CLASS. OFF = 0; CLASS. ON = 1;
P18 CLASS.B. = + 0.0000
Limite inférieure: CLASS. B. = 0; (introduction d'une valeur)
P19 CLASS.H. = + 0.0000
Limite supérieure: CLASS. H. = 0; (introduction d'une valeur)
P23
AFFICH. =
AFFICH.ACTL =
0
AFFICHAGE: ACTUEL = 0; MAINTENIR = 1; STOP = 2;
P30
SENS =
COMPT. POS. =
0
SENS DE COMPTAGE POS. = 0; NEG. = 1;
P36 PS/T. = 36000
PERIODES DE SIGNAL/TOUR = 36000 (introduction d'une valeur);
P37
COMPT. =
COMPT. 0-5 =
5
MODE DE COMPTAGE 0-5 = 5; 0-2 = 2; 0-1 = 1;
P38
VIRG. =
POS.VIRG. 4 =
4
POSITION VIRGULE 4 (plage: 1-8)
P40
CORR. =
CORR. OFF =
0
CORRECTION OFF = 0; LIN = 1; NLIN = 2;
P43
REF = UNE MAR. REF. =
0
UNE MARQUE DE REF. = 0; 500; 1000; 2000; 5000 PG;
P44
REF =
REF. ON =
1
REF. ON = 1; REF. OFF = 0;
P45
ALARME = FRQ.SALISS. =
3
OFF= 0; FRQ.= 1; SALISSURES= 2; FRQ+SALISS. = 3;
P50
V.24 =
9600 BAUD =
9600
VITESSE EN BAUDS = 9600; (110-38400)
P51
V.24 =
INTERLIGNE 1 =
1
INTERLIGNES = 1; (0-99)
P62 A1 = + 0.0000
Limite de commutation 1: A1 = 0; (introduction d'une valeur)
P63 A2 = + 0.0000
Limite de commutation 2: A2 = 0; (introduction d'une valeur)
P79 PRESET = + 0.0000
INIT. PT. DE REF. = 0; (introduction d'une valeur)
P80
ENT-CL =
CL-ENT OFF =
0
CL-ENT OFF =0; CL-ON = 1; CL-ENT ON = 2;
P82
AFF. ON =
ENT..CL ON =
1
AFFICHAGE: ENT...CL ON = 1; ENT...CL OFF = 0;
P85
REF.EXT =
REF.EXT.OFF =
0
REF. EXTERNE OFF = 0; REF. EXTERNE ON = 1;
P86
MOD =
PRINT OFF =
0
TOUCHE MOD: PRINT OFF = 0; PRINT ON = 1;
P98
LANGUE =
LANGUE DE =
1
LANGUE:
0 = EN;
1 = DE;
2 = FR;
*
3 = IT;
4 = NL;
5 = ES;
6 = DA;
7 = SV;
8 = FI;
9 = CS;
10 = PL;
11= HU;
12 = PT;
Caractère de fin (*);
Format de sortie de la liste des paramètres
T2_ND281B.PM6
19.07.2004, 11:05
56