Storage, How to clean the water inlet filter, Engine – DeVillbiss Air Power Company Simoniz S2600 Manuel d'utilisation

Page 15: Pump

Advertising
background image

15- ENG

A08989

HOW TO CLEAN THE WATER

INLET FILTER

This screen filter should be checked

periodically and cleaned if necessary.
1. Remove

filter by

grasping

end and

removing it

from water

inlet of pump

as shown in Fig. 23.

Filter Screen

1. Obtain a funnel

, 6 oz. of RV*

antifreeze, and 16–36" of garden

hose with a male hose connector

attached to one end.

Use only RV

antifreeze. Any

other antifreeze is corrosive and

can damage pump.

STORAGE

ENGINE

Consult the Engine Owner's

Manual for the manufacturer's

recommendations for storage.

2. Disconnect spark plug wire.
3. Connect a hose to water supply

inlet of pump.

4. Add RV* antifreeze to hose as

shown in Fig. 24.

5. Pull engine starter rope slowly

several times until antifreeze

comes out of high pressure hose

connection of pump.

6. Remove hose from water supply

inlet.

7. Reconnect spark plug wire.
*Windshield washer fluid may also be
used

PUMP

The manufacturer recommends using

a pump protector/winterizer when

storing the unit for more than 30 days

and/or when freezing temperatures

are expected. If a pump protector/

winterizer is not available, RV*

antifreeze needs to be run through the

pump as outlined in the steps below.
NOTE: Using a pump protector/

winterizer or RV* antifreeze is to

provide proper lubrication to the

internal seals of the pump regardless

of temperature or environment.

Fig. 23

Fig. 24

2. Clean filter by flushing it with

water on both sides.

3. Re-insert filter into water inlet

of pump.

NOTE: Cone side faces

out.

NOTE: Do not operate pressure

washer without filter properly installed.

Advertising
Ce manuel est liée aux produits suivants: