Installation instructions, Power requirements, Recommended grounding method – DCS CTD-365 Manuel d'utilisation

Page 12

Advertising
background image

10

INSTALLATION INSTRUCTIONS

POWER REQUIREMENTS:

120 VAC, 60 Hz., single phase.

CTD-304/CTD-365: 0.10 Amp. Max.

(Use 15 Amp. circuit minimum)

Always disconnect the electric supply cord from the wall outlet or turn off the electricity at the service

disconnect before servicing this appliance.

Observe all governing codes and ordinances when grounding, in the absence of which, observe National

Electrical Code ANSI/NFPA No. 70-1990.

RECOMMENDED GROUNDING METHOD:

This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized
parallel blades). It must be plugged into a mating grounding-type receptacle, connected to a correctly polarized
120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of
the installer or user to have the existing receptacle changed to a properly grounded and polarized receptacle in
accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes
and ordinances, the receptacle replacement shall be in accordance with the National Electrical Code. THE THIRD
GROUND PRONG SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. The electrical supply must be
a 120 volt, 60 Hz single phase, 15 AMP circuit. The power receptacle must be a NEMA 5-15R device to accept the
three prong plug supplied with the unit.

THIRD GROUND PRONG

COUNTER TOP

GAS SUPPLY

Installer supplied
shut-off valve must
be easily accessible
inside cabinetry

ELECTRIC SUPPLY

4 FOOT POWER CORD

COUNTER TOP

GAS SUPPLY

Installer supplied
shut-off valve must
be easily accessible
inside cabinetry

ELECTRIC SUPPLY

4 FOOT POWER CORD

90

0

Elbow

supplied*
(CT-304
only)

• Required when unit is installed over Wall Oven

REGULATOR

REGULATOR

GAS CONNECTION FOR CTD-365

GAS CONNECTION FOR CTD-304

Advertising