3) Completing the Installation (cont’d)

• Carefully place the air conditioner into the window with the “L”

shaped mounting bracket (on top) positioned in front of the upper

window sash. The bottom of the cabinet should be positioned on

the “recessed” portion of the window frame. Pull the window

down until it rests just behind the front flange of the (top) “L”

shaped mounting bracket (See Fig. 5).

• Expand the shutter frames (fully) on each side and secure the

top of the frames to the window sash using one 3/4” screw on

each side and one in the “L” shaped mounting bracket (Fig. 5).

• Secure the shutter clamp on each side of the (lower) shutter and

secure to window sill using one 3/4” screw on each side (Fig. 5).

• Place the second foam sealing strip to fit the opening between

the inside and outside windows, then attach the safety lock to the

outside window frame using one 3/4” screw (See Fig. 6).

PLEASE NOTE: Window applications come in a variety of

different styles. Therefore, it may be necessary to modify or

improvise your particular installation.

Window sash

“L” Shaped

Mounting

Bracket

Shutter clamps

3/4” screws

Fig. 5

Safety Lock

3/4” screw

Foam Seal

Fig. 6

INSTALLATION INSTRUCTIONS (cont’d)

5

SELECTOR SWITCH: The selector switch controls fan speed and/or cooling

speed. To set desired cooling temperature, simply rotate the SELECTOR knob

to the appropriate setting.

FAN SPEEDS:

LOW FAN

will circulate air at minimum speed without cooling.

HIGH FAN

will circulate air at maximum speed without cooling.

COOLING MODES:

LOW COOL

provides cooling with minimum air circulation.

Recommended for night-time use.

HIGH COOL

provides cooling with maximum air circulation.

Recommended for quick cooling or for extremely hot days. Once room is

cooled, reduce setting to LOW COOL.

OFF shuts-down the unit completely

NOTE: Always allow 3 minutes before switching from one mode to another.

THERMOSTAT: The thermostat automatically controls the (compressor)

cooling cycle and maintains the selected room temperature. To set the

thermostat, rotate the thermostat knob to the desired cooling setting (1 warmest

- 7 coldest). The fan motor will continue to operate after the compressor

(cooling) has cycled off. This is normal.

When using FAN control, turn selector switch slowly, allowing unit to

adjust. When using THERMOSTAT, be sure to allow three minutes

before changing temperature. Adjusting too quickly may cause

compressor to overload.

OPERATING INSTRUCTIONS