Installation instructions (cont’d) – Danby DAC5110M Manuel d'utilisation

Page 5

Advertising
background image

LOCATION

A) This room air conditioner is designed to fit

easily into a single or double hung window. However,

since window designs vary, it may be necessary to

make some modifications for safe, proper installation.

B) Make sure window and frame are structurally

sound and free from dry and rotted wood.

C) For maximum efficiency, install the air conditioner

on a side of the house or building which favours more

shade than sunlight. If the unit is in direct sunlight, it

is advisable to provide an awning over the unit.

D) Provide sufficient clearance around the cabinet to

allow for ample air circulation through the unit (See

Fig. 2). The rear of the unit should be outdoors and

not in a garage nor inside a building. Keep unit as far

away as possible from obstacles/obstructions and at

least 30” above the floor or ground. Curtains and

other objects within a room should be prevented from

blocking the air flow.

E) Be certain the proper electrical outlet is within

reach of the installation. Use only a single outlet

circuit rated at 15 amps. All wiring should be in

accordance with local and national electrical codes.

F) DO NOT install unit where leakage of

combustible gas is suspected. Your air conditioner

may fail to operate in air containing oils (including

machine oils), sulfide gas, near hot springs, etc.

Awning

Fence,

wall, or

other

obstacle

Ground

Side

Obstruction

20”

Min

30”

Min

20”

Min

12” Min

Fig. 2

NOTE: Your unit is designed to evaporate condensation

under normal conditions. However, under extreme

humidity conditions, excess condensation may cause

basepan to overflow to the outside. The unit should be

installed where condensation run-off cannot drip on

pedestrains or neighboring properties.

INSTALLATION INSTRUCTIONS (cont’d)

4

3/8” screws

“L” shaped

mounting bracket

“U” shaped Channel

(Factory Installed)

Fig. 3

Slide down into tabs

Shutter tabs

Shutter

Shutter frame

Fig. 4

1) Assembly of the Upper Channel to Cabinet.

• “L” Shaped Top Channel: Install the “L” shaped channel to the

top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws.

2) Assembly of the Side Curtains to Cabinet.

• Extend the shutter from the shutter frame and slide it into the

shutter tabs on the side channel of the air conditioner, as shown in

Fig. 4.

• Slide the shutters into the top (“L” Shaped) and bottom (“U”

Shaped) channels. The shutters are identified (on frame) as left

and right.

3) Completing the Installation

• Cut the foam (non adhesive) sealing strip to fit the area of the

window sill that the air conditioner will rest on.

Advertising