POSSIBLE CAUSE

1. No fuel in tank

2. Pump pressure incorrect

3. Dirty fuel filter

4. Obstruction in nozzle

5. Water in fuel tank

6. Bad electrical connection

between ignitor and ignition

control assembly

7. Defective ignitor

8. Defective ignition control

assembly

1. Pump pressure incorrect

2. Dirty air intake, air output,

and/or lint filter

3. Dirty fuel filter

4. Obstruction in nozzle

5. Photocell assembly not properly

installed (not seeing the flame)

6. Dirty photocell lens

7. Bad electrical connection

between photocell and ignition

control assembly

8. Defective photocell

9. Defective ignition control as-

sembly

REMEDY

1. Fill tank with kerosene

2. See Pump Pressure Adjust-

ment, page 11

3. See Fuel Filter, page 11

4. See Nozzle Assembly, page 13

5. Drain and flush fuel tank with

clean kerosene. See Storing,

Transporting or Shipping,

page 7

6. Check electrical connections.

See Wiring Diagrams, page 25

7. Replace ignitor, see page 12

8. Replace ignition control as-

sembly

1. See Pump Pressure Adjust-

ment, page 11

2. See Air Output, Air Intake, and

Lint Filters, page 10

3. See Fuel Filter, page 11

4. See Nozzle Assembly, page 13

5. Make sure photocell boot is

properly seated in bracket

6. Clean photocell lens

7. Check electrical connections.

See Wiring Diagrams, page 25

8. Replace photocell

9. Replace ignition control as-

sembly

FAULT CONDITION

Motor starts and runs but heater

does not ignite

Heater ignites but ignition con-

trol assembly shuts heater off

after a short period of time

WARNING: High voltage!

TROUBLESHOOTING

Continued

WARNING: High voltage!

Advertising