UPPER SHELL REMOVAL

1. Remove screws along each side of heater using

5/16" nut-driver. These screws attach upper and

lower shells together. See Figure 11 or 12.

2. Lift upper shell off.
3. Remove fan guard.

Upper Shell

Fan Guard

Figure 11 - Upper Shell Removal,

40/55/70 Models Only

Figure 12 - Upper Shell Removal,

115/165 Models Only

Fan Guard

Upper Shell

Screw

Screw

FAN

IMPORTANT:

Remove fan from motor shaft

before removing motor from heater. The weight

of the motor resting on the fan could damage the

fan pitch (see Figure 13).
1. Remove upper shell (see Figure 11 or 12).
2. Use 1/8" allen wrench to loosen setscrew

which holds fan to motor shaft.

3. Slip fan off motor shaft.

Motor Shaft

Setscrew

Figure 13 - Fan, Motor Shaft, and

Setscrew Location

Motor
Shaft

Fan

Setscrew

Figure 14 - Fan Cross Section

Fan

Flush

Motor

4. Clean fan using a soft cloth moistened with

kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan hub flush

with end of motor shaft (see Figure 14).

7. Place setscrew on flat of shaft. Tighten setscrew

firmly (40-50 inch-pounds/4.5-5.6 n-m).

8. Replace fan guard and upper shell.

AIR OUTPUT, AIR INTAKE AND LINT
FILTERS

1. Remove upper shell (see Figure 11 or 12).
2. Remove filter end cover screws using 5/16" nut-

driver (see Figure 15 or Figure 16, page 11).

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see Preventa-

tive Maintenance Schedule

, page 8).

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output Filter

Figure 15 - Air Output, Air Intake, and

Lint Filters, 40/55/70 Models Only

Advertising