cLEANiNG AND cARE

cHARcOAL FiLTER

Charcoal Filter is used for No-vented, recirculated installation. The filter should be changed every 6 to

12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or by unplugging.
2. Remove 3 screws that secure louver.
3. Pull the louver away from the oven.
4. Slide Charcoal Filter into position on support tabs.
5. Push louver back into place and gently snap tabs into place by hand and replace the 2 screws to

secure louver.

OVEN LiGHT

Remove the louver per instructions 1-3 above and charcoal filter, if used.
4. Slide the light cover forward and lift up.
5. Remove old light bulb and replace only with 20 watt bulb available from a Fisher & Paykel Au-

thorized Servicer or parts distributor. Bulbs are also available at most hardware stores or lighting

centers. DO NOT USE A BULB LARGER THAN 30 WATTS.

6. Replace the oven light cover and charcoal filter, if used; push louver back in place and replace the

louver mounting screws.

Louver

Oven light

Charcoal filter