6

OPERATING

INSTRUCTIONS

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

CAUTION: This appliance

is hot during normal operation,

avoid physical contact.

CAUTION: Do not place

clothing or other combustible

materials on this appliance.

DO NOT operate this heater if any part has been

under water. Call a qualified service technician to

inspect the appliance and to replace any part of

the control system or gas control valve which has

been under water.

LIGHTING HEATER

1. Before attempting to light the heater, smell

all around the heater area for gas. Turn on

the gas supply to the appliance and check all

fittings and connections for gas leaks using a

mild soap and water solution. NEVER use a

match to check for gas leaks. Should a gas leak

occur, shut off the gas supply to the appliance

immediately. Wait a minimum of five minutes

before repairing the leak.

2. Use only the fuel intended for this appliance.

Check the appliance rating plate for the correct

fuel information.

3. Turn the control knob clockwise to the OFF

position. See Figure 1, page 3 and Figure 2

for location of appliance parts.

4. Wait a sufficient length of time (at least five

minutes) to allow gas which may have ac-

cumulated in burner compartment to escape.

5. Turn on the main gas supply.
6. Turn control knob counterclockwise to the

PILOT position.

7a. Press and turn control knob counterclockwise to

PILOT position and hold for 1 to 2 minutes. This

may take longer to purge air from supply hose

depending on length of the hose being used.

Press red spark ignition button to light pilot

flame (repeat until pilot lights) and continue to

hold control knob at PILOT position for 30-60

seconds to enable pilot light safety system. Fully

turn control knob to HI position to light burner.

7b.

To match light the pilot

, move the lighting

hole cover aside (see Figure 2) and place a

lighted match into hole. Press control knob

and hold while lighting and observing pilot

burner. Ensure that pilot burner ignites from

match. Allow pilot to burn approximately 30

seconds before releasing control knob. If pilot

does not remain lit, repeat lighting operation

allowing a longer period of time before releas-

ing control knob.

Note:

In cases where long runs of gas supply lines

have been installed ahead of the appliance, it may

be necessary to bleed trapped air out of supply lines

before lighting pilot. New installations generally

require bleed of supply lines. Wait a minimum of

five minutes after bleeding supply lines before

attempting to light heater.
Adjust pilot if necessary as noted under Pilot

Burner Adjustment, page 7.
8. Turn control knob counterclockwise to the ON

position. The burner will light. DO NOT oper-

ate heater in any position other than full ON.

IMPORTANT:

DO NOT attempt to adjust the

main burner input using the main gas supply valve.

This may cause the pilot and thermocouple to shut

down the burner.

Burner

Filter

Control knob

Thermocouple

Mounting
Brace

Pilot Assembly

Gas Manifold

Combustion
Chamber

Figure 2 - Appliance Parts Identification