LOCATING HEATER

The heater (and propane/LP gas supply cylinder

if applicable) must be located on a hard, flat, level

surface to minimize the risk of accidental tipping. If

an propane/LP gas supply cylinder is used (propane/

LP model only), the cylinder should be adequately

restrained to prevent accidental tipping. DO NOT

operate this heater with the supply cylinder in

any other than the upright position.
This appliance must be installed only in locations

where the potential for physical damage to the

appliance (i.e., due to physical contact) is reduced

to a minimum.
The installer must inform the owner/operator of

this appliance that precautions must be taken to

protect the appliance from physical damage.
This appliance produces radiant heat. Therefore,

it must be located at least 6 feet away from

any propane/LP gas container and must not be

directed toward any propane/LP gas container

within 20 feet.
The heater must be installed in a location such that

it will not be exposed directly to water spray, rain

and/or dripping water.
Use of this heater in a draft/windy area decreases

its efficiency. If possible, operate the unit in a

draft free area.

PIPING

FOR MODEL 125-R (FOR USE WITH
PROPANE/LP GAS ONLY)

This model may be connected to a self-contained

propane/LP gas supply system using the hose and

regulator assembly supplied with the appliance

OR, it may be connected to a permanently installed

propane/LP gas supply system.
If connected to a self-contained propane/LP

gas supply system, the hose assembly must be

inspected prior to each use of the heater. If it is

evident that there is excessive abrasion or wear or

if the hose is cut, it must be replaced prior to the

heater being put into operation.

WARNING: Never use a fork

lift truck type cylinder.

The connection of model 125-R to a propane/LP

cylinder must be made in a well ventilated area

using the regulator and hose assembly supplied

with the appliance. DO NOT attempt to adjust

this regulator. It has been preset at the factory

to provide safe and proper operation of the ap-

pliance. Use a 7/8" open end wrench to connect

the POL fitting (supplied with the propane/LP

regulator) to the propane/LP cylinder. Turn the

POL nut in a counterclockwise direction (left hand

thread) until tight. DO NOT use pipe compound

on POL threads.
The heater must be located at least six feet away

from any propane/LP cylinder and must not be

directed toward any propane/LP cylinder within

20 feet. If more than one heater is used, they

and the supply cylinders must be separated by at

least 20 feet.
The gas supply must be turned off at the propane/LP

supply cylinder when the heater is not in use.
When the heater is to be stored indoors, the connec-

tion between the propane/LP supply cylinder and

the heater must be disconnected and the cylinder

removed from the heater and stored in accordance

with Chapter 5 of the Standard for the Storage and

Handling of Liquefied Petroleum Gases. ANSI/

NFPA 58 (U.S.) OR CAN/CGA B149.2 (Canada)

.

If connected to a permanently installed propane/LP

supply system, the system requires the use of a

two-stage gas regulator assembly which is nor-

mally provided by your propane/LP dealer as part

of the propane/LP supply system. Consult with

your local propane/LP dealer for details concern-

ing proper equipment and installation.

FOR MODEL 125-RN (FOR USE
WITH NATURAL GAS ONLY)

Piping must be clean and free from scale or burrs.
Install regulator supplied with heater. Connect with

1/2" NPT nipple to control valve.
Connect the appliance to an appropriately designed

and installed fuel supply system. This system must

include an approved manual shutoff valve which

is readily accessible and is located within 6 feet

of the appliance. Additionally, a sediment trap or

drip leg must be located upstream of this manual

shutoff valve. Refer to the appropriate (natural gas)

installation code noted above. If a flexible connec-

tor is used, it must be of an approved type.

WARNING: Never use a flame

for gas leak testing.