FRESH FOOD OR FREEZER DOOR DIFFICULT TO OPEN.

• Due to air flow between the compartments, it may be difficult to

open the doors for several seconds after one of them is closed.

DISPENSER WILL NOT DISPENSE WATER OR ICE (SELECT
MODELS).

• A water filter, or the filter bypass plug must be in place.

• Door is open.

• Water supply turned off.

• Water pressure too low.

• Lock switch on.

• Ice jam in the dispenser.

• Ice maker not operating.

WILL NOT RUN.

• Power cord not plugged in.

• No power at the electrical outlet.

• Circuit breaker tripped or house fuse blown.

• Reset control.

• Check Sabbath mode setting.

RUNS TOO LONG/TOO FREQUENTLY.

• Today’s energy efficient refrigerators are larger and require

more running time to maintain stable temperatures.

• Prolonged door openings.

• Too many door openings.

• Condenser needs cleaning.

• The door not sealing (due to a package or a container holding

door open).

• Warm room temperature.

NOISY OPERATION.

• Cabinet not level.

• Weak floor.

• See Normal Operating Sounds

ODOR IN CABINET.

• Odor producing foods should be covered or wrapped.

• Interior needs cleaning.

CABINET VIBRATES.

• Cabinet not level.

• Weak floor.

• Improper installation.

MOISTURE ON INSIDE CABINET WALLS.

• Can occur during hot, humid weather with frequent or prolonged

door openings.

• Door not closed properly.

EXCESSIVE MOISTURE IN OR AROUND DELI DRAWER.

• Food not wrapped properly.

• Hot, humid weather.

REFRIGERATOR COMPARTMENT TOO COLD.

• Refrigerator temperature set too cold.

REFRIGERATOR OR FREEZER COMPARTMENT TOO WARM.

• Refrigerator or freezer temperature set too warm.

• Prolonged door openings.

FREEZER NOT FREEZING PROPERLY.

• Products with high sugar content may not harden completely

when frozen (ice cream, concentrated juice, etc.) Do not store
in door.

• Adjust freezer temperature to a colder setting.

ICE CUBES EVAPORATE.

• Cold air moving over the ice cubes causes shrinkage, especially

with limited usage. This is normal.

AUTOMATIC ICE MAKER NOT OPERATING.

• Wire lever arm in up (OFF) position.

• Water supply turned off.

• Water pressure too low.

• Freezer too warm.

• Install filter or filter bypass.

FRONT CABINET SURFACE WARM TO THE TOUCH.

• Special design to limit condensation during periods of high

humidity.

Before you call for service, please consult the TROUBLESHOOTING GUIDE below.

WARNING

Electric Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in
death, fire, or electrical shock.