Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this troubleshoot-
ing guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby`s Toll Free Number 1-800-263-2629 for assistance.

15

Troubleshooting

N

O

I

T

U

L

O

S

E

S

U

A

C

E

L

B

I

S

S

O

P

M

E

L

B

O

R

P

Air conditioner will
not operate

No power to the unit

Check connection of power cord to power
source.

Check fuse or circuit breaker.

The power cord “RESET” button must
always be pushed in (engaged) for correct oper-
ation.

Inef

¿ cient or no

cooling

• Dirty

air

¿

r

i

a

e

c

a

l

p

e

r

/

n

a

e

l

C

r

e

t

l

¿ lter

Unit size inappropriate for application •

Check with dealer to determine proper unit ca-
pacity for application

• Blocked

air

À

s

e

r

v

u

o

l

r

o

o

d

t

u

o

r

o

ll

i

r

g

m

o

r

f

n

o

i

t

c

u

r

t

s

b

o

e

v

o

m

e

R

w

o

Power interruption, settings changed
too quickly, or compressor overload
tripped

Turn the unit off and wait 5 minutes before at-
tempting to restart

s

t

r

a

p

e

s

o

o

l

n

e

t

h

g

i

T

s

t

r

a

p

e

s

o

o

L

t

i

n

u

y

s

i

o

N

Inadequate support

Provide additional support to unit

Odors

Formation of mold, mildew, or algae
on wet surfaces

Clean unit thoroughly

Place algaecide tablet in base pan

Water dripping
outside

Hot and humid weather

Condensation run-off is normal under these
conditions.

Water dripping inside •

Unit is not properly angled to allow
water to drain outside

Unit must be installed on an angle for proper
condensation run-off. Check the unit and make
any adjustments.

It is an extremely humid day

On an extremely humid day, this effect is expect-
ed. No action required.

Ice or frost build-up

Low outside temperature

When outdoor temperature is approximately
18.3°C (65°F) or below, frost may form when
unit is in cooling mode. Switch unit to FAN (only)
operation until frost melts.

• Unit

air

¿ lter is dirty

Remove and clean

¿ lter

NOTES:

1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a quali

¿ ed technician.

2. When the unit is installed using proper installation steps, the unit is properly tipped toward the outdoors to allow for

condensation run-off.