A warning – Maytag Clothes Dryer Manuel d'utilisation

Page 18

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

Vent system chart

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine
maximum exhaust length, add one 90° turn to the chart.

2. Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the

cardboard. See illustration.

Number of 90°

Type of vent

Box or louvered

Angled hoods

turns or elbows

hoods

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

flexible metal

36 ft (11 m)

28 ft (8.5 m)

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

flexible metal

31 ft (9.4 m)

23 ft (7 m)

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

flexible metal

27 ft (8.2 m)

1 9 ft (5.8 m)

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

flexible metal

23 ft (7 m)

1 5 ft (4.6 m)

Install exhaust hood. Use caulking compound to seal exterior wall opening around

exhaust hood.

1

.

2.

3.

Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust

hood with 4" (1 0.2 cm) clamp.

Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in
"Plan Vent System." Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape,

screws or other fastening devices that extend into the interior of the vent to secure vent.

A WARNING

Excessive Weight Hazard

Use two or more peopie to move and instaii dryer.

Faiiure to do so can resuit in back or other injury.

1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place

cardboard under the entire back edge of the dryer.

3. Examine the leveling legs. Find the diamond marking.

4.

5.

Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the
diamond marking is no longer visible.

Place a carton corner post from dryer packaging under each of the 2 dryer back corners.

Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location.

Leave enough room to connect the exhaust vent.

1. Using a 4" (1 0.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to

existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a
4" (1 0.2 cm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.

3. Once the exhaust vent connection is made, remove the corner posts and cardboard.

CMirt

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use
old hoses.

1. Turn cold water faucet off and remove washer inlet hose.

2. Remove old rubber washer from inlet hose and replace with new rubber washer provided.

If space permits, attach the brass female end of the "Y" connector to the cold water faucet.

NOTE: If "Y" connector can be attached directly to cold water faucet, go to Step 6. If "Y"
connector cannot be attached directly to the cold water faucet, the short hose must be
used. Continue with Step 3.

3. Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on

faucet.

18