Wiring, Connection diagram – Toa N-8400RS Manuel d'utilisation

Page 11

Advertising
background image

11

6. WIrING

6.1. connection Diagram

4P removable terminal plug

(supplied with the N-8400RS)

N-8400RS Substation interface unit

To AC mains or a UPS

(Uninterruptible power supply system)*

Note

RS-450, RS-460,

RS-470, or RS-480

RJ-45 connector

To network

16 lines

To line 3 (orange)

Two pairs of twisted pair cable

To line 4 (yellow)

To line 1 (brown)
To line 2 (red)

Be sure to ground.

1

2

3

If there is a danger of lightning strikes,

insert an appropriate surge arrester

into the power line.

Tips

For more information on the RS-450, RS-460,

RS-470, and RS-480, please refer to their respective

installation manuals.

• This figure represents the RS-450.

[General description of connection]

For cables, refer to p. 13.
1. Power supply connection

Connect the supplied power supply cord to AC

Mains or a UPS (Uninterruptible power supply).

About power supply cord handling

The supplied power supply cord is designed for

exclusive use with the N-8400RS.

Never use it with other equipment.

2. Substation connections

(Refer to p. 13 "Removable Terminal Plug

Connection.")

3. Network connection

Can be connected to a network of 10BASE-

T/100BASE-TX in auto-sensing.

Use a straight through cable of UTP category 5 or

more for this connection.

* Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time. On-line uninterruptible power supply (UPS) is recommended.

reference

Substation interface unit N-8400RS: 35 W (rated) for CE version, 31 W (rated) for CU version

8-Port 10M/100M Switching Hub: Approx. 10 W (Differs depending on products.)