Alarm Recording (Emergency Recording)

Alarm Recording Operation

O

Check that a video cassette with its tab intact has

been inserted.

O Set the MENU/REC LOCK switch to MENU to

display the menu screens. Press the page button to

display the alarm recording setting screen {Menu

Screen 3) on the TV monitor.

[ALARM]

P3

MODE : ;OFyr

DURATION : 30SEC

[RECALL]

O Press the set (+ or -) button to display “2H” or “6H"

for MODE.

MODE :

O Press the shift ( ▼ ) button to move the flashing to

DURATION.
Press the set (+ or -) button to set the recording

duration.

DURATION :

© Upon completion of the settings, set the MENU/

REC LOCK switch to OFF. The regular screen is
restored.

© Press the REC button.

If an alarm input signal is subsequently supplied,

the time mode set to “2H” or “6H”, and alarm

recording continues until the alarm is released.

• If TAPE END on Menu Screen 4 has been set to REPEAT, the auto repeat recording mode is established when the

tape comes to the end. When auto repeat recording is to be performed, use an alarm recording interval setting

other than MANUAL.

• With emergency recording, set the unit to the POWER OFF or STOP mode.

Alarm Recall

The time when the alarm signal was input can be ascertained on the TV monitor by checking the alarm input time in
the RECALL item on Menu Screen 3.

O Set the MENU/REC LOCK switch to MENU to

display the menu screens. Press the page button

to display the alarm recording setting screen (Menu

Screen 3) on the TV monitor.

e

Upon completion of the settings, set the MENU/

REC LOCK switch to OFF. The regular screen is

restored.

[ALARM]

P3

MODE : 2H

DURATION : 30SEC

[RECALL]

10-10-01 20:19

9-14-01 12:05

8-30-01 08:40

6-25-01 04:14

[OUTPUT SELECT]

TERMINAL OUT i ERR WARN

The alarm recall function stores up to 4 alarm input times in the memory and displays them on the screen. If there

have been more than 4 inputs, they will be deleted from the screen in sequence starting with the oldest data.

When the RESET button is pressed while Menu Screen 3 is on the display, the alarm recall memory can be cleared.