Regency Horizon HZ54EPV Foyer

à Gaz

installation

Description

Simpson

Direct Vent Pro

®

Metal-Fab™

Sure Seal

Attic Insulation Shield 12”

58DVA-IS

N/A from FPI

N/A

High Wind Vertical Cap

58DVA-VCH

N/A

High Wind Horizontal Cap

N/A

N/A

Horizontal Square Termination Cap

N/A

5DHT

Vertical Termination Cap

N/A

5DVT

Storm Collar

58DVA-SC

5DSC

Restrictor Disk

58DVA-RD

N/A

Colinear Flex Connectors

N/A

N/A

Adjustable Flashing 0/12-6/12

58DVA-F6

5DF

Adjustable Flashing 6/12-12/12

58DVA-F12

5DF1-2

Vinyl Siding Standoff

58DVA-VSS

5DVS

Vinyl Siding Shield Plate

N/A

N/A

Snorkel Termination 14”

58DVA-SNK14

N/A

Snorkel Termination 36”

58DVA-SNK36 (N/A - FPI)

N/A

Basic Horizontal Termination Kit (A)

N/A

N/A

Horizontal Termination Kit (B)

58DVA-KHA

N/A

Vertical Termination Kit

58DVA-VHA

N/A

FPI

946-604/P

Simpson Direct Vent -Vent Guard (Optional)

946-623/P

AstroCap XL Horizontal Cap

770-994

Rigid Pipe Adaptor (Must use with all rigid piping)

946-506/P

Vent Guard (Optional)

946-606

Starter collar reducer 5” x 8” to 4” x 6-5/8”

946-625

Vinyl Siding Standoff - AstroCap XL

Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length

(L)

5” x 8” Venting

For specifi c instructions on venting components - visit the
manufacturers website listed below.

Run (X)

Rise (Y)

0” (0mm)

5-11/16” (144mm)

15-5/16” (389mm)

Simpson Direct Vent Pro: www.duravent.com

9” (229mm)

10-15/16” (278mm)

20-9/16” (522mm)

Metal-Fab Sure Seal: www.mtlfab.com

12” (305mm)

13” (330mm)

22-11/16” (576mm)

Industrial Chimney Company: www.icc-rsf.com

24” (610mm)

21-7/16” (697mm)

31-1/16” (789mm)

Note: Horizontal runs of vent must be level, or have a 1/4”
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.

36” (914mm)

29-13/16” (757mm)

39-7/16” (1002mm)

48” (1219mm)

38-1/4” (972mm)

47-7/8” (1216mm)

Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com

L676 & L900 DIRECT VENT FIREPLACE

• A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
• Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.

IMPORTANT NOTE