Regency B36XTE Foyer à gaz à évent direct

INSTALLATION

Description

Simpson

Direct Vent Pro

®

Selkirk

Direct Temp™

Metal-Fab™

Sure Seal

ICC Excel

Direct

Attic Insulation Shield 12”

58DVA-IS

N/A from FPI

N/A

N/A

N/A

High Wind Vertical Cap

58DVA-VCH

N/A

N/A

TM-5VT

High Wind Horizontal Cap

N/A

N/A

N/A

TM-5DHT

Horizontal Square Termination Cap

N/A

5DT-HHC

5DHT

TM-5HT

Vertical Termination Cap

N/A

5DT-HVC

5DVT

TM-5VT

Storm Collar

58DVA-SC

5DT-SC

5DSC

TM-SC

Restrictor Disk

58DVA-RD

N/A

N/A

TM-5DS

Colinear Flex Connectors

N/A

N/A

N/A

N/A

Adjustable Flashing 0/12-6/12

58DVA-F6

5DT-AF6

5DF

TF-5FA

Adjustable Flashing 6/12-12/12

58DVA-F12

5DT-AF12

5DF1-2

TF-5FB

Vinyl Siding Standoff

58DVA-VSS

5DT-VS

5DVS

TM-VSS

Vinyl Siding Shield Plate

N/A

5DT-VSP

N/A

N/A

Snorkel Termination 14”

58DVA-SNK14

N/A

N/A

TM-5ST14

Snorkel Termination 36”

58DVA-SNK36 (N/A - FPI)

N/A

N/A

TM-5ST36

Basic Horizontal Termination Kit (A)

N/A

5DT-HKA

N/A

N/A

Horizontal Termination Kit (B)

58DVA-KHA

5DT-HKB

N/A

N/A

Vertical Termination Kit

58DVA-VHA

5DT-VKC

N/A

N/A

FPI

946-604/P

Simpson Direct Vent -Vent Guard (Optional)

946-623/P

AstroCap XL Horizontal Cap

770-994

Rigid Pipe Adaptor (Must use with all rigid piping)

946-506/P

Vent Guard (Optional)

946-606

Starter collar reducer 5” x 8” to 4” x 6-5/8”

946-625

Vinyl Siding Standoff - AstroCap XL

Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length

(L)

5” x 8” Venting

For specifi c instructions on venting components - visit the
manufacturers website listed below.

Run (X)

Rise (Y)

0” (0mm)

5-11/16” (144mm)

15-5/16” (389mm)

Simpson Direct Vent Pro: www.duravent.com

6” (152mm)

8-13/16” (224mm)

18-7/16” (468mm)

Selkirk Direct-Temp: www.selkirkcorp.com

9” (229mm)

10-15/16” (278mm)

20-9/16” (522mm)

Metal-Fab Sure Seal: www.mtlfab.com

12” (305mm)

13” (330mm)

22-11/16” (576mm)

Industrial Chimney Company: www.icc-rsf.com

24” (610mm)

21-7/16” (697mm)

31-1/16” (789mm)

Note: Horizontal runs of vent must be level, or have a 1/4”
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.

36” (914mm)

29-13/16” (757mm)

39-7/16” (1002mm)

48” (1219mm)

38-1/4” (972mm)

47-7/8” (1216mm)

L676 & L900 DIRECT VENT FIREPLACE

• A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
• Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.

IMPORTANT NOTE

Note: Mettre les conduits d’évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu’à la sortie.
S’assurer qu’aucune section du système d’évacuation n’est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
un risque d'incendie.