TROUBLESHOOTING GUIDE

21

Before calling a service provider try the trouble shooting sugges-

tions below.

Ice Machine Operation

Ice machine does not operate

Is the ice machine’s power cord plugged in? Plug the power

cord into a grounded 3 prong outlet.

Is the selector switch in the front grille set to the “ON” posi-

tion? Check the switch to be sure it is in the “ON” position.

Is a fuse blown or a circuit breaker been tripped? Replace a

blown fuse or reset a tripped circuit breaker.

Is the temperature of the room cooler than it normally is? The

minimum room temperature is 55°F (13°C). The bin thermistor

may be sensing the room temperature and shut off before the

bin is full of ice. If the room temperature remains low the ice

machine may not restart.

Is there a drain pump in the ice machine? If a large amount of

water was added to the ice machine then you should wait a few

minutes for the drain pump to dispose of it. If there is still water

in the ice bin check the drain pump vent line and drain line for

obstructions or kinking.

The ice machine is noisy

Many sounds of an ice machine are different than your house-

hold refrigerator. This subject is discussed on page 17, but check

the following:

Do you hear water being circulated in the ice machine? This is

a normal sound as water is added once every ice making cycle.

Is there a “whoosing” sound? Make sure water is getting to

the ice machine. Also check to make sure the drain plug is fully

seated in the water reservoir.

Is there an ice slab caught between the evaporator plate and

the grid cutter? First check to see if the ice machine is level. If

the ice machine is level run a cleaning cycle.

Ice Production

Little or no ice production from the ice machine

Is the selector switch set to the “ON” position? Check the

switch to be sure it is in the “ON” position.

Is water getting to the ice machine? Make sure nothing is

disrupting the water supply such as a closed water valve or a

blown fuse or tripped circuit breaker.

Has the ice machine just been started? A typical ice production

cycle can take up to 11/2 hours. Initial start up cycles can take

longer. Check the ice machine after 24 hours for ice accumula-

tion in the bin.

Is the reservoir drain plug in place? Check that the reservoir

drain plug is properly seated.

Is the water distributor tube restricted? Run a cleaning cycle to

clean the ice machine. Also check any filters to make sure they

are not restricted.

Is the condenser fan air flow restricted? Make sure the grille in

the front of the ice machine is open for proper air circulation.

Is the room and/or water temperature to warm? Move the ice

machine to an area where the ambient temperature is below

90°F (32°C). The ice machine should not be placed next to a

heat source such as an oven. Check the cold water connection.

Is there scale build up in the ice machine? If there is scale build

up on the evaporator, the ice machine needs to be cleaned. See

“Cleaning the Ice machine”.

Ice Quality

Odor, grey color, or off taste in the ice

Is there mineral scale build up on the evaporator plate? The

ice machine needs cleaning. See “Cleaning the Ice Machine”.

Is there a high mineral content in the water? The water may

need to be filtered.

Are food items being stored in the ice bin? Remove food from

the ice bin.

Clumps of ice

Are there clumps of ice in the bin? If the ice isn’t used on a

regular basis it will melt and form into clumps. Break up the ice

clumps with the ice scoop.

Ice cubes are too big, too small, or hollow

Is there low ice consumption? Ice is slowly melting in the

ice bin which will affect the size of the cubes. This is normal

operation. When the ice bin needs to be replenished, cubes will

return to the regular size.

Is the ice slab releasing? Clean the evaporator. See “Cleaning

the Ice Machine”.

Is the distributor tube restricted? Check the water line to the

ice machine to make sure there are no restrictions or kinks in

the line. Check all filters to make sure they are not restricted.

Check that the water flows evenly out of the distributor tube, if

not, clean the ice machine. See “Cleaning the Ice Machine”.