TROUBLESHOOTING YOUR BEVERAGE CENTER

Problem

Possible Cause

Remedy

Unit not cold enough

Adjust temperatures (See “Set Tempera-

tures” on page 6)

• Control set too warm

• Content temperature not stabilized.

• Excessive usage or prolonged door

openings.

• Airflow to front grille blocked.

• Door gasket not sealing properly.

• Adjust temperature colder. Allow 24

hours for temperature to stabilize.

• Allow temperature to stabilize for at

least 24 hours.

• Airflow must not be obstructed to

front grille. See “clearances” on

page 4.

• Check door alignment and/or replace

door gasket.

Unit too cold

Adjust temperatures (See “Set Tempera-

tures” on page 6)

• Control set too cold

• Door gasket not sealing properly.

• Adjust temperature warmer. (See

page 6, “set temperature”). Allow 24

hours for temperature to stabilize.

• Check door alignment and/or replace

door gasket.

No interior light.

• Failed light bulb

• Replace light bulb, see page 16.

Light will not go out when door is closed

• Door not activating light switch.

• Display light is turned on.

• Unit not level, level unit, (See page 4,

“leveling legs”)

• Verify the door is aligned properly,

refer to page 10 for instructions.

• Turn off display light, shut door.

Noise or Vibration

• Unit not level

• Level unit, see “Leveling Legs” on

page 4.

Unit will not run.

• Unit turned off

• Power cord not plugged in.

• No power at outlet.

• Turn unit on. See “Starting your appli-

ance” on page 6.

• Plug in power cord.

• Check house circuit.

Before you call for service

If the unit appears to be malfunctioning, read through this

manual first. If the problem persists, check the troubleshooting

guide below. Locate the problem in the guide and refer to the

cause and its remedy before calling for service. The problem may

be something very simple that can be solved without a service

call. However, it may be required to contact your dealer or a

qualified service technician.

Electrocution Hazard

- Never attempt to repair or perform

maintenance on the unit until the main electrical power has

been disconnected. Turning the units control “off” does not

remove electrical power from the units wiring.