oPeration and maintenanCe

The height of the fountain is determined

by several factors:

pump size, as estimated in the earlier table

How deep the pump is positioned in the water;

lowering the pump increases the flow since the

discharge is also lowered

the two valve adjustments on the Diverter Valve (see

information above)

• To maintain the correct flow and fountain head patterns,

both the fountain heads and the pump screens will require

occasional cleaning.

Pump Cage - Do not remove the upper or lower pump cage

while operating the pump. failure to operate the pump

without the filter cage or operating the pump with a broken

cage will allow large debris to enter the pump causing the

pump to fail voiding the warranty.

Pump Cage Cleaning - we recommend inspecting your

AquaJet

on a regular basis to make sure it is functioning

properly. if you notice the water flow rate diminish it may

be due to the pump’s filter cage becoming clogged with

debris. Always disconnect the power before performing

maintenance on the pump. in many cases the clogged filter

cage can be cleaned by simply reaching in the pond or

pulling the pump out of the water and removing debris from

the filter cage. the pump can also be removed from the

pond and the debris stuck to the pump filter cage can be

removed or sprayed off with a garden hose.

• If the pump is

not on a level

base, loosen the

riser stem collar

and adjust the

orientation of

the riser stem to

keep the fountain

head vertical.

• If the pump is not on a level base, loosen the riser stem

collar and adjust the orientation of the riser stem to keep the

fountain head vertical.

• If not using the Fountain Kit, the Diverter Valve or

the Multi-Hose Adapter can be used to supply

water to an accessory such as a spitter, external

filter or waterfall.

if using the diverter or multi-Hose adapter to supply

water to an additional filter, fountain or waterfall, it is

recommended to not position the pump in the deepest

portion of the pond. this will protect the fish by preventing

the pond from completely draining in case of leak in the

plumbing or filter, fountain or waterfall. bricks or stones can

be used if needed to raise the pump off the bottom.

• Connect pump to an outlet that is protected by a ground

fault interrupter. once the pump is running and water

circulating through the filter(s) or waterfall, check for any

fitting or waterfall leaks where the external connections

are made.