Electric dryer power hookup – canada only, Electrical requirements, Warning – Whirlpool WGD4870BW Manuel d'utilisation

Page 6

Advertising
background image

6

GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.

WARNING:

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.

ELECTRIC DRYER POWER

HOOkUP – CANADA ONLY

Electrical Requirements

It is your responsibility:

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate

and in conformance with the Canadian Electrical Code,

C22.1-latest edition and all local codes. A copy of the

above codes standard may be obtained from: Canadian

Standards Association, 178 Rexdale Blvd., Toronto, ON

M9W 1R3 CANADA.

To supply the required 4 wire, single phase, 120/240 volt,

60 Hz., AC only electrical supply on a separate 30-amp

circuit, fused on both sides of the line. A time-delay fuse or

circuit breaker is recommended. Connect to an individual

branch circuit.

Installation spacing for recessed area or closet

The dimensions shown are for the minimum spacing allowed.

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door, and

floor moldings.

Additional spacing of 1" (25 mm) on all sides of the dryer is

recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

Companion appliance spacing should also be considered.

Mobile home – Additional installation requirements

This dryer is suitable for mobile home installations. The

installation must conform to the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part 3280

(formerly the Federal Standard for Mobile Home Construction

and Safety, Title 24, HUD Part 280) or the Canadian

Manufactured Home Standard CAN/CSA-Z240 MH.

Metal exhaust system hardware, available for purchase.

For further information, please reference the “Assistance

or Service” section of the “Use and Care Guide.”

Special provisions must be made in mobile homes to

introduce outside air into the dryer. The opening (such

as a nearby window) should be at least twice as large

as the dryer exhaust opening.

This dryer is equipped with a CSA International Certified

Power Cord intended to be plugged into a standard 14-30R

wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure

wall receptacle is within reach of dryer’s final location.

4-wire receptacle (14-30R)

Do not use an extension cord.

If using a replacement power supply cord, it is recommended that

you use Power Supply Cord Replacement Part Number 8579325.

For further information, please reference the “Assistance or

Service” section of the “Use and Care Guide.”