Install vent system, Make gas connection, Install exhaust hood – Whirlpool WGD4870BW Manuel d'utilisation

Page 12: Plan pipe fitting connection, Connect vent to exhaust hood, Connect gas supply to dryer, Vent system chart, Open shut-off valve

Advertising
background image

12

Install Vent System

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

A

B

C

D

Plan pipe fitting connection

2.

A combination of pipe fittings must be used to connect dryer

to existing gas line. A recommended connection is shown.

Your connection may be different, according to supply line

type, size, and location.

A. 3/8" flexible gas connector

B. 3/8" dryer pipe

C. 3/8" to 3/8" pipe elbow

D. 3/8" pipe-to-flare adapter fitting

Open shut-off valve in supply line; valve is open when handle

is parallel to gas pipe. Then, test all connections by brushing

on an approved noncorrosive leak-detection solution.

Bubbles will show a leak. Correct any leaks found.

†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.

Connect vent to exhaust hood

2.

Vent must fit over the exhaust hood. Secure vent to exhaust

hood with 4" (102 mm) clamp. Run vent to dryer location

using straightest path possible. Avoid 90° turns. Use clamps

to seal all joints. Do not use duct tape, screws, or other

fastening devices that extend into interior of vent to secure

vent, because they can catch lint.

A

B

Connect gas supply to dryer

1.

Remove red cap from gas pipe. Using a wrench to tighten,

connect gas supply to dryer. Use pipe-joint compound

on threads of all non-flared male fittings. If flexible metal

tubing is used, be sure there are no kinks.

NOTE: For LP gas connections, you must use pipe-joint

compound resistant to action of LP gas. Do not use

TEFLON

®†

tape.

Make Gas Connection

Vent System Chart

(29" Wide Long Vent WED/WGD4870 Models Only)

Number of

90° turns

or elbows

Type

of vent

box/louvered, or

Angled hoods

1

4

3

2

0

Rigid metal

160 ft. (48.8 m)

150 ft. (45.7 m)

140 ft. (42.7 m)

130 ft. (39.6 m)

120 ft. (36.6 m)

Rigid metal

Rigid metal

Rigid metal

Rigid metal

5

110 ft. (33.5 m)

Rigid metal

Open shut-off valve

3.

A

B

Closed valve

Open valve

Non-flared

male fitting

Flared

male fitting