Sunlite ST40Y48M10X6- Manuel d'utilisation

Solid state led st40 strip light swivel mount c

Advertising
background image

M

odel

M

ax

I

nput

V

oltage

(V

dc

)

M

ax

c

urrent

(a)

M

ax

W

attage

ST40

48

3.5

66

Important Safety InStructIonS - Save theSe InStructIonS

uSe only wIth claSS 2 power unIt

• These products are only suitable for connection to a Class 2 power source

and have not been evaluated for use when connected to a power source

that does not comply with Class 2 voltage and energy limited supplies.

cautIon - to prevent the rISk of fIre, do not InStall In

a compartment Smaller than 10 IncheS by 10 IncheS by

(xx+12) IncheS (where xx IS the length of the lumInaIre In

IncheS)

all InStallatIonS of SunStrIp40 Should be

performed by a certIfIed electrIcIan and be In

complIance wIth the natIonal electrIcIanS code aS well

aS local codeS.

SuItable for wet locatIonS

conSIgneS de SÉcurItÉ ImportanteS - conServeZ SoIgneuSement ceS InStructIonS

a utIlISer unIQuement avec une Source d’alImentatIon de

claSSe 2

• Ces produits doivent être branchés uniquement à une source d’alimen-

tation de classe 2 et n’ont pas été testés pour une utilisation lors d’une

connexion à une source d’énergie non conforme à la tension de classe 2

et à l’approvisionnement en énergie limitées.

attentIon - pour ÉvIter leS rISQueS d’IncendIe, ne paS

InStaller danS un compartIment InferIeur a 10 pouceS

Sur 10 pouceS Sur (xx+12) pouceS (oÙ xx eSt la longueur

du lumInaIre en pouceS).

ce produIt doIt Étre InStallÉ Selon le code

d’InStallatIon pertInent, par une perSonne QuI connaÍt

bIen le produIt et Son fonctIonnement aInSI Que leS

rISQueS InhÉrentS.

convIent aux emplacementS mouIllÉS.

E338721

F

ixture

W

iring

:

Solid State led
St40
Strip light
Swivel mount

C

ertiFiCation

:

UL and cUL

Damp/Wet Location Listed

IP64/IP66 Rated

e

nergy

:

>0.9 Power Factor

700-1400mA / ~ 48VDC

-30° C to 40°C

C

ontaCt

:

4811 Quail Crest Place

Lawrence, KS 66049

www.sunlitest.com

T:785.856.0219

F

ixture

i

nStallation

i

nStruCtionS

:

SunStrip40 - “St40-” - low voltage claSS 2 led luminaire

Suggested wiring utilizes bullet connections in alignment with the direction of current flow from the driver.

turn power off before any inStallation, inSpection or removal of fixture/wiring.

Strip

Driver

W (-)

W (+)

B (-)

R (+)

Side with clip is positive.

inStructionS below are for one of the two mountS on the fixture. repeat theSe StepS for the other mount.

Cut 1-1/8” hole in ceiling.

Drill 1-1/16” hole in ceiling. Hole location should be

near where the fixture wires will be once mounted on

ceiling. Drill two holes for the #8 screws.

Retrieve wires in ceiling and outfit with bullet

connections.

• Side of wire closer to LED driver should be fitted with

a female bullet connector.

• Side of the wire farther from the LED driver should be

fitted with a male bullet connector.

Outfit fixture wire with bullet connections.

• Core (+) with a male bullet connector.

• Shield (-) with a female bullet connector.

1

2

3

Connect fixture wires and ceiling wires together (See

Fixture Wiring Diagram). Place fixture in desired

location and insert two #8 screws to secure the fixture.

#8 ScrewS are Supplied by otherS.