Important Safety InStructIonS - Save theSe InStructIonS

uSe only wIth claSS 2 power unIt

• These products are only suitable for connection to a Class 2 power source

and have not been evaluated for use when connected to a power source

that does not comply with Class 2 voltage and energy limited supplies.

cautIon - to prevent the rISk of fIre, do not InStall In

a compartment Smaller than 10 IncheS by 10 IncheS by

(xx+12) IncheS (where xx IS the length of the lumInaIre In

IncheS)

all InStallatIonS of SunStrIp40 Should be

performed by a certIfIed electrIcIan and be In

complIance wIth the natIonal electrIcIanS code aS well

aS local codeS.

SuItable for wet locatIonS

E338721

F

ixture

W

iring

:

Solid State led
St40
Strip light
receSSed

Surface Mount

C

ertiFiCation

:

UL and cUL

Damp/Wet Location Listed

IP64/IP66 Rated

e

nergy

:

>0.9 Power Factor

700-1400mA / ~48 VDC

-30° C to 40°C

C

ontaCt

:

4811 Quail Crest Place

Lawrence, KS 66049

www.sunlitest.com

T:785.856.0219

F

ixture

i

nStallation

i

nStruCtionS

:

Cut or drill a 1-1/8” hole in ceiling.

Retrieve wires in ceiling and outfit

with bullet connections.

• Side of wire closer to LED driver

should be fitted with a female

bullet connector.

• Side of the wire farther from the

LED driver should be fitted with a

male bullet connector.

Thread fixture wire through ceiling

mount. Outfit fixture wire with bullet

connections.

• Core (+) with a male bullet

connector.

• Shield (-) with a female bullet

connector.

SunStrip40 - “St40-” - low voltage claSS 2 led luMinaire

Suggested wiring utilizes bullet connections in alignment with the direction of current flow from the driver.

Connect bullet connections from

light fixture and from ceiling wires

together.

1

2

3

4

5

Push wires into ceiling. Hold fins

flush to ceiling mount body and

insert into the ceiling.

turn power off before any inStallation, inSpection or reMoval of fixture/wiring.

Strip

Driver

W (-)

W (+)

B (-)

R (+)

Side with clip is positive.

inStructionS below are for one of the two MountS on the fixture. repeat theSe StepS for the other Mount.

conSigneS de SÉcuritÉ iMportanteS - conServeZ SoigneuSeMent ceS inStructionS

a utiliSer uniQueMent avec une Source d’aliMentation de

claSSe 2

• Ces produits doivent être branchés uniquement à une source d’alimen-

tation de classe 2 et n’ont pas été testés pour une utilisation lors d’une

connexion à une source d’énergie non conforme à la tension de classe 2

et à l’approvisionnement en énergie limitées.

attention - pour Éviter leS riSQueS d’incendie, ne paS

inStaller danS un coMpartiMent inferieur a 10 pouceS

Sur 10 pouceS Sur (xx+12) pouceS (oÙ xx eSt la longueur

du luMinaire en pouceS).

ce produit doit Étre inStallÉ Selon le code

d’inStallation pertinent, par une perSonne Qui connaÍt

bien le produit et Son fonctionneMent ainSi Que leS

riSQueS inhÉrentS.

convient aux eMplaceMentS MouillÉS.