PROBLEM

CAUSE

SOLUTION

Machine will not operate

Missing or blown fuses
Key in the ‘OFF’ position
Low battery charge
Machine is connected and charging

Fit or replace fuse (page 23)
Turn key to ‘ON’ position (page 9)
Charge batteries (page 22)
Take off charge (page 22)

Vacuum will not operate

Waste water tank full

Empty waste water tank (page 19)

Poor water pick-up

Waste-water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter cloogged/blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor-tool blades
Low battery charge

Empty waste-water tank (page 19)
Remove and clean (page 10)
Push tight connections (page 10)
Remove and clean (page 19)
Remove and clean (page 19)
Clean and refit (page 19)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Recharge batteries (page 22)

No brush / scrub function

No brushes fitted
Brush deck raised

Check and fit (page 11)
Lower brush deck (page 14)

Little or no water flow

Clean-water tank empty
Clean-water tank filter blocked/ clogged
Incorrect water flow setting
Brush deck raised

Fill clean-water tank (page 19)
Remove and clean (19)
Adjust as desired (page 15)
Lower brush deck (page 14)

Little or no dosing solution flow

Chemical dosing tank empty
incorrect dosing flow setting

Fill dosing-tank (page 13)
Adjust as desired (page 15)

Machine just ‘stops’ while
operating

To much load on the brush system

Reset the machine using the key and
decrease the brush load to best suit
the floor type (page 19)