Breakaway floor-tool

Fig.33

The floor-tool design incorporates a breakaway feature.

Allowing it to safely disengage from its mounting should it

become caught on an obstruction, during forward machine

movement (Fig 33).

Fig.34

To re-attach the blade to its holder.

First loosen the retaining knobs on the floor-tool body and slide

onto the holding bracket.

Tighten retaining knobs to finger tight (Fig 34).

Machine Operation

Machine in use

ALWAYS ENSURE THAT THE FLOOR IS PRE-SWEPT

AND RELEVANT SAFETY SIGNS ARE DISPLAYED.

NOTE: Care must be taken to reduce speed when
cornering or when manoeuvring around obstacles

!

!

To operate, turn the master control on/off key to the ‘ON’ position,

select water flow rate, chemical mix (see page 15), lower the floor

tool (see page 14) and select forward (see page 9: Fig 4), press

the start / stop trigger.

Vacuum pick-up, water-flow and chemical-dose will turn on

automatically and the machine will move forward.

Adjust the speed to suit the conditions using the variable speed

control (see page 9).

The clean water / chemical mix is dispersed evenly via

‘THRU- FEED’ scrubbing brushes.

The waste water is then retrieved by the suction floor-tool.

Overlap each scrubbing path by 10cm to ensure

an even clean.

Do not operate the machine on inclines that exceed (9%), when

full.

On heavy soiled floors.

First pre-scrub the floor with the floor-tool in the raised position,

allow the chemical time to work then scrub the area a second

time with the floor-tool lowered (Fig 35).

If streaking occurs wipe floor-tool blades clean (Fig 36).

On heavily soiled floors use a ‘double scrub’ technique.

Fig.35

Fig.36