* Within the appliance enclosure a 6” clearance between the top of the vent pipe and combustible materials is
required. All other clearances within the enclosure, including where the vent pipe exits the enclosure are sub-
ject to 2” to the sides and bottom and 3” to the top for horizontal and 1” for vertical.
** See venting section.
IMPORTANT:
The LHD50SS requires a minimum inside enclosure height of 60”, measured from the bottom of
the appliance. For temperature requirements, this area must be left unobstructed. It is recommended that the
enclosure be ventilated at the top and bottom to circulate the hot air.
Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different
modes, see “OPERATION” section. Check pressure readings, see “PILOT BURNER ADJUSTMENT” section.
Once fi nished in, access to the control components can only be done through the inside of the appliance.
5.3 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
!
WARNING
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG
INTO THE APPLIANCE OPENING.
STEEL STUD
FRAME
TOP OF ENCLOSURE
6”*
0” IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND
STONE.
3”
2”
COMBUSTIBLE
NON-COMBUSTIBLE
60”
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
APPLIANCE
OPENING
28”
MINIMUM
32”
MINIMUM
COMBUSTIBLE
MATERIAL
51”
MINIMUM
PLUS
RISE**
NON-COMBUSTIBLE
NOTE: JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND
CRACKING SHOULD BE USED WHEN
TAPING AND MUDDING SEAMS.
9” TO
SIDEWALL