W415-0769 / A / 12.10.10

It’s important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.

54.2

3/8” - 1/2”

FLAME MUST

ENVELOPE UPPER

3/8" TO 1/2" OF

THERMOCOUPLE &

THERMOPILE

AIR SHUTTER OPENINGS

LP

1/2”

NG

3/16”

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame color to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED