Sample, Warning, 4 rating plate information – Napoleon Fireplaces STARfire 52 - HDX52 Manuel d'utilisation

Page 7: Model propane / propane modèle, Model natural gas / gaz natural

Advertising
background image

7

W415-1276 / A / 05.09.14

EN

2.4 RATING PLATE INFORMATION

NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is equipped with a remote control system, which
requires batteries (supplied) to be installed. The transmitter takes 1
9V battery and in the case of a power failure the receiver takes 4 “AA”
batteries.

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.

The illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

NOTE: The rating plate must remain with the appliance at all times. It must not be removed.

65%

HDX52

SAMPLE

Both the rating plate and lighting instructions are attached to a cable and inserted along the left side of the ap-
pliance.

!

WARNING

ALLOW APPLIANCE TO COOL BEFORE PERFORMING ANY MAINTANCE OR CLEANING.

W385-1928

CHDX52N

CHDX52P

&(57,),('81'(5+202/2*8(6(/21/(61250(6$16,=E‡&6$E9(17('*$6),5(3/$&()2<(5­*$=9(17,/e

NOT FOR USE WITH SOLID

FUEL. FOR USE WITH

GLASS DOORS CERTIFIED
:,7+7+,681,721/<

WARNING:

'2127$''$1<0$7(5,$/

TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
7+$76833/,('%<7+(0$18)$&785(5

WITH THE APPLIANCE
'(&25$7,9(352'8&7127)2586($6$

HEATING APPLIANCE.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS:

TOP 0"

FLOOR 0"

RECESSED DEPTH

29"

SIDES 0"

BACK 0"
9(17723



9(176,'(6 %27720



9(57,&$/9(17



MANTEL 6"*
7236,'(6 %$&.3(567$1'2))63$&(56)25)5$0,1*

MATERIALS. FOR FINISHING MATERIALS SEE OWNER’S MANUAL
*MAXIMUM HORIZONTAL EXTENSION 2". SEE INSTRUCTION MANUAL FOR GREATER
EXTENSIONS. SEE OWNER’S INSTRUCTION MANUAL FOR MINIMUM AND
MAXIMUM LENGTHS.

(/(&75,&$/5$7,1*9+=/(667+$1$03(5(6
WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

63e&,),&$7,216e/(&75,48(69

60HZ. MOINS DE 12 AMPÈRES.

HDX52N

HDX52P

MODEL PROPANE /

PROPANE MODÈLE

UN COMBUSTIBLE SOLIDE NE
3$6È75e87,/,6e$9(&&(7

$33$5(,/87,/,6(5$9(&/(6

3257(9,75e(6

+202/2*8e(66(8/(0(17

$9(&&(77(81,7e

$'9(57,66(0(17

N’AJOUTEZ PAS

$&(7$33$5(,/$8&810$7e5,$8'(9$17
(175(5(1&217$&7$9(&/(6)/$00(6
$875(48(&(/8,48,(67)2851,$9(&7

CET APPAREIL PAR LE FABRICANT.
352'8,7'e&25$7,)1(3$687,/,6(5

COMME APPAREIL DE CHAUFFAGE

'e*$*(0(1760,1,0$8;'(60$7e5,$8;

COMBUSTIBLES :
DESSUS 0"
PLANCHER 0"
352)21'(85'(/·(1&/$9()$&("
&Ñ7e6

"

ARRIÈRE 0"
'(6686'8&21'8,7'·(9(17

"

&Ñ7e6(7'(66286'8&21'8,7
'·(9(17

"

&21'8,7'·(9(179(57,&$/

"

TABLETTE 6"*

'(6686&Ñ7e6 $55,Ë5(6(/21/(6(63$&(856'(
'e*$*(0(173285/(60$7(5,$8;'·266$785(6(/21
/$0$18(/'(35235,e7$,5(3285/(60$7e5,$8;'(

FINITION. *L’EXTENSION HORIZONTALE MAXIMALE : 2".
5e)e5(5$80$18$/'·,16758&7,213285'(6
(;7(16,2163/86*5$1'(65e)e5(5$80$18(/
'·,167$//$7,21'(35235,e7$,5(

MODEL NATURAL GAS /

GAZ NATURAL

0-4500FT (0-1370M)

$/7,78'(e/e9$7,21 0-4500FT

(0-1370M)

55,000

BTU/H

INPUT / ALIMENTATION 55,000

BTU/H



%78+ 5('8&(',1387$/,0(17$7,215e'8,7( ,500 BTU/H

3.5

"

WATER COLUMN/D’UNE COLONNE D’EAU

MANIFOLD PRESSURE / 10

"

WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION

AU

COLLECTEUR

4.5

"

WATER COLUMN/D’UNE COLONNE D’EAU

0,1,0806833/<35(6685( 11

"

WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION D’ALIMENTATION MINIMALE

7.0

"

WATER COLUMN/D’UNE COLONNE D’EAU

0$;,0806833/<35(6685( 13

"

WATER COLUMN/D’UNE COLONNE D’EAU

PRESSION D’ALIMENTATION MAXIMALE

65.2%

P.4 FE

65.2%

SERIAL NUMBER/ NO. DE SÉRIE:

HDX52

/·$33$5(,/'2,7e9$&8(56(6*$=(187,/,6$17
/·(16(0%/('·e9$&8$7,2135235($1$32/(215e)e5(5
$80$18(/'·,167$//$7,21'(35235,e7$,5(3285
/·(9$&8$7,2135(&,6(,/(67,03257$17'(%,(1
5e,167$//(5(75(6&(//(5/·(9(17$35e6$92,5$6685e
/(0$,17,(1'86<67e0('(35,6('·$,5

7+($33/,$1&(0867%(9(17('86,1*7+($335235,$7(

1$32/(219(17.,766((2:1(56,167$//$7,210$18$/

)259(17,1*63(&,),&63523(55(,167$//$7,21$1'

5(6($/,1*,61(&(66$5<$)7(56(59,&,1*7+(9(17$,5

,17$.(6<67(0

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE
CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. VENTED GAS FIREPLACE. APPROVED FOR
BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME
INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES
GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLA-
TIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A

INSTALLER L’APPAREIL SELON LES CODES D’INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU
GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE
MAISONS MANUFACTUREE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ÉTATS-UNIS NE
PEUT ETRE APPLIQUÉE, SE REFERER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES
COMMUNAUTÉS, ANSI/NFPA 501A.

9700539 (WSL)

4001658 (NAC)

4001657 (NGZ)

4001659 (WUSA)

OPTIONAL FAN KIT: NZ64

(16(0%/('(9(17,/$7(85)$&8/7$7,)1=