ECM-2 PROGRAMMABLE CONTROL - OPERATING MODES

1. Turn the main switch "ON" (1).
2. The light inside the proofer will turn ON and the digital control will indicate a code. Then,

"PREH" will flash.

3. "PREH" will be displayed on the control until it reaches the set temperature.
4. To check and modify:

Temperature settings : Press and hold down for 2 seconds the temperature

key and adjust with the UP and DOWN arrows. Then,

press temperature key to save data or " red

" to

exit without saving.

Humidity settings :Press and hold down for 2 seconds the humidity key and

adjust with the UP and DOWN arrows. Then, press

humidity key to save data or "red

" to exit without

saving.

5. When the control reaches the set parameters, "PREH" will disappear and the timer display will

appear.

To start the timer, press " green

", the timer will stop blinking and start countdown.

At the end of the countdown an alarm will go off and " READY " will appear on the display.

Press " red

" to stop the alarm.

6. When proofing cycle is completed, turn "OFF" (0) the switch.
When the proofer is not in operation, open the doors to let out the humidity and to prevent
mould.
P.S.

The doors should not be opened unnecessarily to conserve the heat and humidity in the
proofer.
Every day cleaning of the water pan under the proofer's doors should be exercised.