Doyon JAOP14 Manuel d'utilisation

Page 20

Advertising
background image

A-17
Steam

□ 1

st

parameter can be: OFF, ON, PULSE.

○ If OFF, steam remains off for duration of step.
○ If ON, steam remains on for duration of step.
○ If PULSE, pulsed steam is enabled for duration of step.

□ Default is OFF for all steps / programs (no steam).

Pulse-Steam

□ Steam parameter (see above) must be set to PULSE.
□ Pressing Pulse-Steam allows programming TON 0.02 seconds by default.
□ Pressing Pulse-Steam a 2

nd

time allows programming TOFF 0.30 seconds by default.

□ Default is OFF for all steps / programs (no steam).

Fan

□ 1

st

parameter can be: OFF, ON, PULSE.

○ If OFF, fan remains off for duration of step.
○ If ON, fan remains on for duration of step.
○ If PULSE, pulse fan is enabled (pulse mode for duration of step).

■ Pressing Fan a 2

nd

time allows programming TON 02.30 minutes by default.

■ Pressing Fan a 3

rd

time allows programming TOFF from 0.25 seconds by default.

□ Default is PULSE for all steps/programs.

Rack
(Functional only with oven models with rotating racks).

□ Rack must be enabled in low-level programming to be useable.
□ This can be ON or OFF for each step.
□ Default is ON for all steps / programs, if enabled in low-level programming.

Step End

□ Step End defines what happens with the end of a Cook Program Step (Stop key is used to

program Step End parameter).
○ AUTO: nothing happens, automatically move on to the next step (buzzer output remains

off).

○ WARN: move on automatically to the next step, but turn on buzzer output for 5 seconds.
○ MANUAL: activates buzzer output until user manually presses Start key to enable next

step.

○ LAST: activate buzzer output until user manually presses Stop key to end the recipe.

□ Default is AUTO for all steps / programs.

Food Probe in Programming Mode
□ Food temperature can be programmed to the following settings OFF ON MONITOR.

○ ON: using food temperature’s programming set point to end the current step at that

temperature.

○ OFF: default for all steps / programs.
○ MONITOR: to ignore food probe temperature, but still display the information if

requested.

Advertising