Operation conditions, Room freeze protection function (rfp), Power supply – Panasonic CS-XE12PKUA Manuel d'utilisation

Page 9

Advertising
background image

9

English

Operation conditions

Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature

Temperature (°F/°C)

Indoor

Outdoor

DBT

WBT

DBT

WBT

COOL

Max. 89.6/32

73.4/23

114.8/46

78.8/26

Min. 60.8/16

51.8/11

0.0/-18

-/-

HEAT

Max. 86.0/30

-/-

75.2/24

64.4/18

Min. 60.8/16

-/-

0.0/-18

-2.2/-19

The human activity sensor will also scan for area of heat source and movement in a room.

Detection area

• The human activity sensor performance is infl uenced by indoor unit location, movement

speed, temperature range, etc.

• The human activity sensor may:

- mistakenly detect an object with heat source & movement similar to human, such as

pets, etc.

- mistakenly detect as non-heat source & movement if a human stays motionless for

certain period of time.

• Do not place large objects near the sensor and keep away heating units or humidifi er

from the sensor’s detection area. They may cause sensor malfunction.

23ft/7m

120º

Room Freeze Protection Function (RFP)

Room Freeze Protection function (RFP) is used in spaces that are unoccupied during the winter, for the purpose of
protecting any equipment or appliances which may be destroyed as a result of freezing temperature.

To select Room Freeze Protection
When selected, the unit will circulate the air in High mode for monitoring the temperature. When the sensor detects the
temperature drops below 46°F / 8°C the compressor/heat pump operation begins, when the temperature reaches 50°F /
10°C, the compressor stops and repeat this cycle.

ROOM FREEZE PROTECTION FUNCTION (RFP) OPERATION
When the RFP is selected, the unit will operate the fan at high speed for proper room temperature monitoring. When the
sensor detects that the room temperature has dropped below 46°F / 8°C, the compressor/heat pump operation begins.
When the room temperature reaches 50°F / 10°C, the unit shuts off, then will repeat continuously if the temperature
drops below 46°F / 8°C again.

<Disclaimer>
This function may not be performed if the unit is not energized, or under a certain condition that unit is unable to operate
such as in protection mode. Please consult with the HVAC installers or professional for details.

The Room Freeze Protection function (RFP) cannot be used unless the unit is energized and set into the RFP mode.
In the advent of a power failure this mode will not function. During the RFP mode, POWERFUL OPERATION, QUIET
OPERATION and FAN SPEED selection are all disabled. Please consult with you HVAC installer or professional for
more details.

To

learn more...

Power Supply

Models Number

Time Delay Circuit

Breaker

Rated Volts

CS/CU-XE9PKUA

15 Amps

208/230V

CS/CU-XE12PKUA

20 Amps