Alignment and adjustments – Samsung WA5451ANW-XAA Manuel d'utilisation

Page 5

Advertising
background image

ALIGNMENT AND ADJUSTMENTS

5

Quick Test Mode:

1. All LED’s light up and it sends out Beep Sound when it

enters into the Quick Test Mode. (Including 7-Segment)

2. Displays software version for a sec and Clear EEprom.
3. When the version is displayed, turn the Jog-Dial so that

the version disappears. Press the following keys to test the
various components.
- Temp Key : Water Valve Test
- Signal : Door Lock/Unlock Test
- Soil Key : Water Heater Test
- Spin : Drain / circulation pump test

EEPROM Clear Check

Definition of EEPROM Clear Mode:

- EEPROM initialization.
- All course/option settings are to be reset to default

values after EEPROM initialization.

- When Service arises and it needs PCB replacement,

EEPROM should be reset.

How to Enter:

- The unit needs to be on.
- Press Delay Start Key, and Power Key at the same

time.

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING

WA5471ABP_03051A-02(Technical information).indd 5

2012-02-13 �� 9:36:23

Advertising