Trouble shooting, Problem checking and method of pcb, Warning – Samsung WA5451ANW-XAA Manuel d'utilisation

Page 17

Advertising
background image

17

Hall Sensor Check

Check Voltage at Pin #4 and #3 of CN1

Tester Check = DC0.6V

Check Voltage at Pin #4 and #2 of CN1

Tester Check = DC0.6V

Motor Check

Resistance at Pin #1 of CN8 and GND

= 280

Resistance at Pin #2 of CN8 and GND

= 280

Resistance at Pin #3 of CN8 and GND

= 280

Drain Motor_Pump Check

Check Voltage at Pin #3 of CN6 and Pin #9 of CN4

When Drain Pump operates = AC 120V

Water Valves/ Check

Check Voltage at Pin #3 of CN6 and Pin #1,2,3,4 of CN4

When Valves operates = AC 120V

Clutch-Motor

Check Voltage at Pin #3 of CN6 and Pin #8 of CN4

When Valves operates = AC 120V

Pump

Check Voltage at Pin #3 of CN6 and Pin #7 of CN4

When Valves operates = AC 120V

Heater Relay Check

Check Voltage at Pin #1 of CN8 and Pin #1 of RY13

When Heater Relay operates = AC 120V

AC Power Check

Check Voltage at Pin #1 and #3 of CN6

Check Voltage at Pin #1 of CN6 and Pin #2 of RY13

Tester Check = AC 120V

Door Lock Check

Check Voltage at Pin #3 and #5 of CN3

When Door Lock = DC 6.5V

PROBLEM CHECKING AND METHOD OF PCB

- If you plug in the power cord and turn Power S/W on, memorized data is displayed.

If any data is not displayed, check the followings.

Thermistor Check

Check Resistance at Pin #9 and #7 of CN8

Tester Check = 47

Water Sensor Check

Check Frequency at Pin #11 and #7 of CN8

Reset frequency = 25.6KHz

Check Frequency at Pin #12 and #7 of CN8

Reset frequency = 25.6KHz

TROUBLE SHOOTING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer

before servicing, unless testing requires power.

WARNING