Alignment and adjustments, Data display mode, System check mode – Samsung DV456ETHDSU-AC Manuel d'utilisation

Page 4: Warning

Advertising
background image

4

Data Display Mode

Definition of Temperature Display Mode:
-

Display Mode 0 : Temperature data(Celsius)

-

Display Mode 1 : Average Touch Sensor data for 1 minute

-

Display Mode 2 : Average Temperature(Celsius) data for 1minute

How to Enter:
-

With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a

beeping sound .

-

If not pressed any keys for 5 minutes, it will be set back from Data Display Mode

-

If pressing AdjustUp Key in this mode ,Display Mode ID will be increased.

-

If pressing AdjustDown Key in this mode ,Display Mode ID will be decreased.

• Converting °C °F

Celsius(°C)

-30

-10

10

30

50

70

F =9/5C + 32

Fahrenheit(°F)

-22

14

50

86

122

158

System Check Mode

Definition of System Check Mode:
-

“ t2 ” will display.

-

System Check Mode(t2 mode) Progress Function Performed Start/Pause
Motor(CW) Relay On  Heater Relay On  Heater Relay Off, Motor(CW) Relay Off

How to Enter:
-

While in Power Off, pressing the Dry Level + Power keys simultaneously will put the dryer into

the System Check mode

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Hudson steam dryer_Technical_information_DC68-03171C-01_EN.indd 4

2012-11-17 15:10:31

Advertising
Ce manuel est liée aux produits suivants: