ERROR ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one
of the Error Displays from the following errors.

Error Display

Trigger

Action Taken

tE

The Thermistor resistance is
very low or high.

Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.

HE

Invalid heating Temp in running
the dryer

Check for:
- Restricted vent system.
- Check Thermistor resistance.

dE

Running the dryer with door
open

Check for:
- Close the door, and run the dryer
- Loose or open wire terminals in Door
Sense circuit.

dF

Invalid door state for more than
256 milliseconds

Check for:
- Loose or open wire terminals in Door
Sense circuit.

bE2

Invalid state of key circuit short
for 30 secs

Check for:
- Display PCB key circuit short or not

FE

Invalid power source Frequency

Check for:
- Not using regular power source frequency
- Invalid power frequency sense circuit

AE

Electronic Control Problem
(Communication Error)

Check for:
- Check PCB and Wire harness.
- Replace PCB.

Et

Invalid state of EEPROM
communication

Check for :
- PCB with Eeprom circuit.

2E

Electronic control problam
(Over Voltage Error)

Check for:
- Check PCB and Wire harness.
- Check Power supply
- Replace PCB

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.