Trouble shooting, Warning, Component testing procedures – Samsung DV50F9A8GVP-A2 Manuel d'utilisation

Page 8: Centrifugal switch (motor)

Advertising
background image

8

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

COMPONENT TESTING PROCEDURES

Component Electrical Testing (with ohmmeter)

Thermistor resistance 10K Ω @ 25°C 77°F

Thermostat 1 resistance < 1Ω

Thermostat 3 resistance < 1Ω

- If resistance is infinity, replace thermostat 3.

Thermostat 2 resistance < 1Ω

- If resistance is infinity, replace thermostat 2.

Heater resistance 10 Ω

- If resistance is infinity, replace Heater.

Measure resistance of the following terminal

1) Door switch : Off

Terminal : “COM” - “NC” (1-3) : <1Ω
Terminal : “COM” - “NO” (1-2) : ∞ Ω

2) Door switch : On

Terminal : “COM” - “NC” (1-3) : ∞ Ω
Terminal : “COM” - “NO” (1-2) < 1Ω

Belt Cut-off S/W

- Lever open: Resistance value < 1Ω

- Lever push: Resistance value : ∞ Ω

Vent Sensing - Thermistor Resistance

238.23K Ω @ 25

℃ 77℉

Motor (Electronic & GAS)

Contacts

= Contact closed

Centrifugal Switch (Motor)

2.88Ω between
Pin# 3 and 4

3.5Ω between
Pin# 4 and 5

Function

1M

2M

3M

5M

6M

Start

Run

F900A DRY_DV50F_TECH MANUAL_DC68-03171D_EN(邀请翻译成法语).indd 8

2013-1-21 13:55:32

Advertising