Alignment and adjustments, Error items and diagnostic codes, Warning – Samsung DV350AEP-XAA Manuel d'utilisation

Page 2

Advertising
background image

2

ERROR ITEMS AND DIAGNOSTIC CODES

An occurrence of an Error will make a sound of error melody for 5sec and con tinuously show one
of the Error Displays from the following errors.

Error Display

Trigger

Action Taken

LED

LCD

tS

to

tE

The Termistor resistance is very
low or high.

Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.

hE

HE

Invalid heating Temp in running
the dryer

Check for:
- Restricted vent system.
- Check Thermistor resistance.

do

dE

Running the dryer with door
open

Check for:
- Close the door, and run the dryer
- Loose or open wire terminals in
Door Sense circuit.

dF

Invalid door state for more than
256 milliseconds

Check for:
- Loose or open wire terminals
in Door Sense circuit.

bE

bE2

Invalid state of key circuit short
for 30 secs(all models)
75 secs(DV339,DV338,DV448,D
V438,DV428)

Check for:
- Display PCB key circuit short or not

FE

Invalid power source Frequency

Check for:
- Not using regular power source
frequency
- Invalid power frequency sense circuit

9E

Electronic Control Problem
(Communication Error)

Check for:
- Check PCB and Wire harness.
- Replace PCB

od

Invalid Dry time in excess Dry
time

Check for:
- Sensor bar Open
- using Adjust time Up excessively

Et

Invalid state of Eeprom
communication

Check for :
- PCB with Eeprom circuit.

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.

Technical_information-02365G-00_EN.indd 2

2011-09-21 �� 3:07:08

Advertising
Ce manuel est liée aux produits suivants: