Inverter parameter

Sam-100-12

Input

bATTerY SYSTeM VoLTAGe

12 VDC

NOMINAL INPUT VOLTAGE

13.8 VDC

INPUT VOLTAGE RANGE

10.8 VDC to 15.4 VDC

NO LOAD CURRENT

0.3A ± 0.1A

output

OUTPUT VOLTAGE WAVE FORM

Modified Sine Wave

OUTPUT VOLTAGE

115 VAC +10% / -2%

OUTPUT FREQUENCY

60 Hz ± 5%

OUTPUT POWER, CONTINUOUS (RESISTIVE LOAD)

100W

OUTPUT POWER, SURGE (<1 SEC., RESISTIVE LOAD)

200W

PEAK EFFICIENCY (AT 50% OF CONTINUOUS POWER) 90%

USB CHARGING PORT

USB 3.0, Connector Type "A": 5 VDC, 2.1A

protectIonS

LOW INPUT VOLTAGE SHUTDOWN

10.5 VDC.± 0.3VDC. Auto reset at

11.5 VDC. ± 0.3VDC

HIGH INPUT VOLTAGE SHUTDOWN

15.4 VDC.± 0.2VDC. Auto reset at

15.0 VDC.± 0.2VDC

OVERLOAD AND GROUND

FAULT SHUT DOWN

Yes. Latches in shutdown condition. Manual

reset: remove the inverter from the 12V

Power outlet. Wait for 3 min and re-insert

firmly.

OVER TEMPERATURE SHUTDOWN

Yes. Auto reset on cooling down.

CooLING fAN

1 - Always oN.

INPUT FUSE: INSIDE TOP OF THE 12V POWER

PLUG PORTION

10A, 250V (fast Acting, Type AGC-10;

Dimensions: 0.25" x 1.25")

connectIonS

DC INPUT CONNECTION

12 V Power Plug (Cigar Plug)

AC OUTPUT CONNECTION

one NeMA5-15r outlet

monItorInG

STATUS INDICATION

GREEN LED: ON - NORMAL; OFF - SHUT

DoWN

GeneraL

OPERATING TEMPERATURE RANGE

0°C to 25°C / 32°F to 77°F at 100% loading;

26°C to 35°C / 78.8°F to 95°F at 80% loading

OPERATING HUMIDITY

< 80%; Non-condensing

seCtIOn 7 |